{"product_id":"cx1020-n060-beckhoff-cx-series-ethernet-system-interface-module","title":"CX1020-N060 BECKHOFF Module d'interface système Ethernet série CX","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCX1020-N060 (CX1020N060)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Ethernet system interface expansion designed specifically for the Beckhoff CX1020 Embedded PC series. This module provides a dedicated 10\/100 Mbit\/s communication port, enabling seamless vertical integration between field-level control and enterprise-level networking. Engineered for mission-critical B2B environments such as power distribution, smart manufacturing, and large-scale HVAC control, the CX1020-N060 ensures stable data throughput and low-latency connectivity. By offloading communication tasks to this modular interface, engineers can maintain high CPU performance on the primary controller while expanding the system's networking capabilities in a compact, DIN-rail mounted form factor.\u003c\/p\u003e\n\u003ch3\u003eHardware Architecture and System Integration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCX1020-N060\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a modular extension that connects directly to the CX1020 CPU via the internal system bus. It features a single\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRJ45\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnection point supporting standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCat 5\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecabling. A critical architectural constraint for system designers is that this module is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enot combinable with the CX1100-0004\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower supply unit; instead, it must be paired with other CX1100-xxxx series power supplies to ensure proper bus communication and voltage regulation.\u003c\/p\u003e\n\u003cp\u003eThis interface is more than a simple media converter; it is an active system component that draws power directly from the system bus, eliminating the need for external wiring for the module's logic. With its ultra-slim\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e19 mm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewidth, it allows for high-density hardware configurations without compromising the thermal profile of the control cabinet.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCX1020-N060\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBECKHOFF\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Transfer Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\/100 Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x RJ45\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 m (Cat 5)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVia system bus (CX1100-xxxx)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to +85 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19 mm x 100 mm x 51 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 80 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConforms to EN 60068-2-6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the CX1020-N060 with a CX1100-0004 power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCX1020-N060\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically documented as incompatible with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCX1100-0004\u003c\/strong\u003e. You must use alternative power supply modules within the CX1100 range to ensure system stability and bus compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum distance supported for the Ethernet connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports a maximum cable length of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 m\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCat 5\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecabling. For distances exceeding this limit, industrial switches or signal repeaters must be integrated into the network topology.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require manual IP configuration via hardware switches?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfiguration is typically handled through the TwinCAT software environment or the operating system of the CX1020 Embedded PC, allowing for flexible DHCP or Static IP assignment based on your network architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing and Interference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite the robust EMC immunity (conforming to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEN 61000-6-2\u003c\/strong\u003e), always route the Ethernet Cat 5 cable away from high-current power lines and VFD output cables. Use shielded RJ45 connectors to maintain signal integrity in high-noise industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Connection Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the module is firmly snapped onto the DIN rail and that the side-mounted PC104 bus connectors are clean and free of debris before mating the module with the CX1020 CPU. A loose bus connection can cause intermittent communication \"Time-Out\" errors in TwinCAT.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain the recommended installation position to allow for vertical convection. Since the module operates up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e55 Celsius\u003c\/strong\u003e, ensuring clear airflow at the top and bottom of the module prevents localized hotspots that could degrade data transfer rates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCX1020-N060\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for longevity in harsh environments, boasting significant vibration and shock resistance (EN 60068-2-6\/27). This makes it an ideal choice for mobile automation units or machinery subjected to constant mechanical stress. Its ability to operate in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e95% non-condensing humidity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures reliability in diverse climates, from tropical manufacturing plants to refrigerated logistics centers. By utilizing the modular \"N-series\" interface, users gain the flexibility to scale their networking requirements without replacing the core processing unit, ensuring long-term investment protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106704482667,"sku":"CX1020-N060","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx1020-n060-ew2p2ivswcp.png?v=1776244132","url":"https:\/\/www.plcprotech.com\/fr\/products\/cx1020-n060-beckhoff-cx-series-ethernet-system-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}