{"product_id":"danfoss-060g1372-industrial-compact-pressure-transmitter","title":"Danfoss 060G1372 Transmetteur de pression compact industriel","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1372 (060G1372)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a robust pressure transmitter engineered for high-precision control in heavy industrial automation. Tailored for deployment in commercial boiler systems, cooling towers, hydraulic lines, and municipal water distribution networks, this field-tested instrument provides stable analog current feedback. By continuously monitoring pressure metrics and transmitting data to a central PLC or Distributed Control System (DCS), the sensor enables real-time optimization of pump speeds and valve positions. This precision tracking effectively minimizes fluid hammer risks, prevents cavitation anomalies, and helps avoid unpredicted plant shutdowns, ensuring maximum equipment efficiency.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hardware features an acid-resistant stainless steel body containing a piezoresistive sensing element designed to resist mechanical shock and cyclic stress. To ensure long-term stability, the internal electronics utilize a fixed calibration framework that isolates the sensor from drift caused by ambient mechanical resonance. Integrated diagnostics enforce strict signal clipping thresholds between 3.6 mA and 22.4 mA, allowing automation controllers to instantly distinguish valid pressure fluctuations from wiring faults or signal shorts. The internal control board is further protected by an IP65-rated enclosure, shielding the circuitry from ambient humidity, splashing process water, and airborne particulates.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G1372\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 40 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Loop\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrecision\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.5% (Typical) \/ +\/- 1.0% (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverload Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProcess Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG 1\/4 Male (EN 837)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 100 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePg 11 Angular\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIngress Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox 1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do the integrated signal clipping parameters assist with diagnostics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor bounds its output; values shifting to 3.6 mA or 22.4 mA signify a fault. Because these values reside outside the standard 4-20 mA band, the supervising PLC can flag a field component defect without mistaking it for a legitimate process pressure change.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this gauge transmitter require atmospheric venting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. As a relative gauge transmitter, it references ambient atmospheric pressure. The reference channel is integrated into the connector structure, allowing the sensor to compensate for barometric fluctuations while maintaining an IP65 environmental seal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the zero point be adjusted in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This instrument utilizes a laser-welded, factory-sealed architecture with no mechanical trim potentiometers. This fixed design prevents calibration drift caused by continuous vibration and eliminates the risk of unauthorized field adjustments.\u003c\/p\u003e\n\u003ch3\u003eMechanical Installation \u0026amp; Wiring Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Port Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThread the G 1\/4 male fitting into a port counter-bored to EN 837 specifications. Use a calibrated torque wrench on the 27 mm hex base to tighten the transmitter to 30-35 Nm. Do not rotate the upper cylindrical body by hand, as this risks breaking internal seal joints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTerminate the positive power lead to Pin 1 and the negative return path to Pin 2 of the Pg 11 angular connector. Ensure the perimeter rubber seal is seated flush inside the connector cap before tightening the retaining screw to maintain the IP65 environmental seal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAcoustic and Shock Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn systems with fast-cycling hydraulic loops or high-frequency piston pumps, install an upstream dampening orifice or siphon loop. While the sensor accommodates 100 bar surges, continuous exposure to cavitation peaks can degrade the structural integrity of the internal diaphragm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102412071275,"sku":"060G1372","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1372-yqgu1o2xfcb.png?v=1776136918","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-060g1372-industrial-compact-pressure-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}