{"product_id":"danfoss-060g1540-mbs-3000-compact-pressure-transmitter-0-6-bar","title":"Transmetteur de pression compact MBS 3000 0-6 Bar Danfoss 060G1540","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1540 (060G1540)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, compact pressure transmitter from the renowned Danfoss MBS 3000 series, specifically engineered for use in a vast range of industrial applications. This precision-engineered sensor measures pressure across a 0 to 6 bar (0 to 87 psi) range, converting the physical input into a standard 4 to 20 mA current signal. Designed for reliability in harsh environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1540\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a critical component for hydraulic systems, water treatment plants, and air compressors. Its robust construction ensures exceptional vibration stability and long-term signal consistency, effectively reducing maintenance overhead and preventing costly system downtime in high-demand B2B industrial sectors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe MBS 3000 series architecture focuses on balancing precision with mechanical durability to thrive in volatile industrial conditions.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides a linear 4 to 20 mA current output, offering high immunity to electromagnetic interference (EMI) and making it ideal for long-distance signal transmission to PLCs or remote displays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBoasts an impressive maximum overload pressure of 36 bar (522 psi), which is six times its nominal operating range, providing a massive safety margin against catastrophic hydraulic spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperates on a wide supply voltage range from 9 to 32 VDC, allowing for seamless integration into diverse power architectures without the need for additional voltage regulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with a standard angular connector (Male\/Female) that facilitates rapid field installation and secure electrical contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMedia Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically designed to withstand cavitation, liquid hammer, and pressure peaks, ensuring the internal sensing element remains accurate throughout its operational life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G1540 (MBS 3000)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 6 bar (0 to 87 psi)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 - 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverload Pressure Max\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36 bar (522 psi)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAngular Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.186 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 060G1540 handle extreme pressure spikes in hydraulic lines?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MBS 3000 is built with a high overload pressure rating of 36 bar. This means the sensor can withstand transient spikes up to six times its rated 6 bar capacity without mechanical failure or permanent calibration shift, making it highly reliable in systems with rapid valve closures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat electrical connection is required for this transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model uses a standard industrial angular connector. It provides a \"Male and Female\" interface, meaning it typically includes the plug-and-socket set required to secure the cable, ensuring an IP-rated seal that protects against dust and moisture ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this sensor be used in outdoor installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the MBS 3000 series is designed for rugged industrial use. When properly installed with its angular connector and appropriate cable, it provides high resistance to environmental factors. However, ensure the ambient temperature stays within the standard -40 to 85 deg C operating range.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Port Orientation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor gas applications, mount the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1540\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the pressure connection facing upwards to allow any condensate to drain away from the sensing element. For liquid applications, mount it with the connection facing downwards or sideways to prevent air pockets from affecting the 4 to 20 mA signal accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI Protection and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure maximum signal precision, use a shielded twisted-pair cable for the 4 to 20 mA loop. The shield should be connected to the functional earth of the PLC or control cabinet to dissipate high-frequency noise common in environments with variable frequency drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSealing and Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the transmitter into a threaded manifold, use the appropriate sealing washer or thread sealant recommended for your specific medium. Avoid over-tightening, as excessive torque can stress the stainless steel housing and potentially lead to a zero-point shift in the reported pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102415282539,"sku":"060G1540","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1540-ycw0qxhcxqp.png?v=1776136919","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-060g1540-mbs-3000-compact-pressure-transmitter-0-6-bar","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}