{"product_id":"danfoss-061b010966-pressure-switch-kp-series","title":"Interrupteur de pression Danfoss 061B010966 Série KP","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 061B010966 (061B010966)\u003c\/strong\u003e is a ruggedized pressure switch designed for precise control and protection within demanding industrial fluid systems. Engineered for high reliability in sectors such as power generation, water treatment, and chemical processing, this device serves as a critical safety barrier to regulate system pressures and prevent equipment over-pressurization. By utilizing a high-performance bellows sensing element, the \u003cstrong\u003e061B010966\u003c\/strong\u003e provides repeatable, long-term service, effectively minimizing mechanical wear and reducing the frequency of unplanned downtime in heavy-duty process control environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 061B010966 features a robust internal architecture centered on a fatigue-resistant bellows mechanism, ensuring accurate response to pressure fluctuations. The unit is encapsulated in an IP65-rated housing, which provides protection against moisture ingress and particulate contamination, allowing for reliable operation in both indoor plant environments and sheltered exterior locations. The switch utilizes a standardized G-type pressure connection, facilitating seamless integration into existing industrial piping frameworks. The electrical interface is handled via a Pg 11 cable gland, designed to maintain seal integrity while ensuring vibration-resistant connectivity in dynamic environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e061B010966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eDenmark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e-0.20 to 1.00 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Test Pressure\u003c\/td\u003e\n\u003ctd\u003e15.0 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing Element\u003c\/td\u003e\n\u003ctd\u003eBellows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Connection\u003c\/td\u003e\n\u003ctd\u003eG-thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003ePg 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the intended application of the bellows sensing element?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe bellows sensing element is selected for its high sensitivity and ability to provide consistent performance over millions of operational cycles. It is ideal for pressure regulation loops where high repeatability is required to maintain stable process conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this pressure switch be used with chemical media?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe wetted parts are designed for standard industrial applications involving water, air, and neutral fluids. For specific chemical compatibility or highly aggressive media, please verify that the bellows material meets your process safety requirements prior to commissioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the recommended approach for setting the pressure threshold?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit allows for manual adjustment within its specified range. After installation, verify the switching point using a calibrated reference gauge to ensure the trip setpoint matches your system requirements. Ensure the Pg 11 gland is fully tightened to prevent moisture ingress post-adjustment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this part currently supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, this model is a standard component within the Danfoss KP pressure switch series. We maintain new, original stock to ensure rapid availability for your maintenance or project requirements.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines and Safety Measures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Install the switch on a rigid, vibration-isolated surface. Excessive mechanical vibration can lead to erratic switching or premature fatigue of the internal bellows. If mounting directly on a pipeline, ensure the pipe is braced to minimize resonance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Termination:\u003c\/strong\u003e Tighten the Pg 11 cable connection to ensure a secure, splash-proof fit. If the switch is deployed in an environment with high electromagnetic interference, use shielded wiring and ground the shield at the control panel to prevent induced contact chatter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Safety:\u003c\/strong\u003e Always depressurize the process line and isolate the electrical supply before performing any installation or maintenance tasks. Never exceed the 15.0 bar test pressure limit, as doing so may cause mechanical deformation of the bellows, resulting in permanent damage and failure of the control loop.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102409875819,"sku":"061B010966","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/061b010966-anqpl4pwpxt.png?v=1776136961","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-061b010966-pressure-switch-kp-series","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}