{"product_id":"danfoss-080g0294-mmigrs2-canbus-control-panel","title":"Panneau de contrôle CANBUS Danfoss 080G0294 MMIGRS2","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e080G0294 (080G0294)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDanfoss\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMMIGRS2 series remote display and control interface designed for the MCX programmable controller range. In complex industrial environments such as commercial HVAC systems, large-scale refrigeration plants, and district heating stations, this unit functions as the primary Human-Machine Interface (HMI). By providing real-time data visualization and parameter adjustment via a robust CANBUS communication link, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMMIGRS2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that technicians can maintain peak system efficiency, significantly reducing diagnostic time and preventing unplanned downtime in mission-critical thermal management applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e080G0294\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is centered around seamless integration with the Danfoss MCX ecosystem. Utilizing the CANBUS (CANopen) protocol, it allows for high-speed data exchange over long distances between the controller and the user interface.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogic Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in 2 Digital Inputs and 1 Digital Output allow the panel to act as a localized control node, capable of triggering alarms or receiving remote start\/stop signals independent of the main controller's onboard I\/O.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe LCD display is optimized for industrial legibility, providing clear feedback on system variables, setpoints, and active alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Power Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware supports both 24 VAC and 24 VDC power supplies, offering flexibility for various control cabinet power architectures (50\/60 Hz).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgrammability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAs a programmable controller accessory, its interface can be customized using Danfoss software tools to match specific application requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e080G0294\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControl Panel (MMIGRS2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCANBUS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VAC \/ 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs (DI)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 pc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Outputs (DO)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 pc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Mounting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLCD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.185 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 080G0294 hot-swappable on an active CANBUS network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile CANBUS is robust, it is recommended to power down the specific branch before connecting the MMIGRS2 to avoid voltage spikes or bus errors that could disrupt the communication of other nodes on the network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I address the MMIGRS2 if multiple panels are on the same bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit's node ID must be uniquely configured within the MCX software environment. Ensure that the baud rate matches the master controller and that proper termination resistors are used if this is the end-of-line device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum cable distance for the CANBUS connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe distance depends on the baud rate; however, for standard industrial applications, distances up to 500 meters are achievable with high-quality shielded twisted-pair cabling, provided the signal integrity is maintained.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCANBUS Wiring Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways use shielded twisted-pair cable for the CANBUS connection. The shield should be grounded at a single point (typically at the main controller) to prevent ground loops while protecting the data signal from Electro-Magnetic Interference (EMI) generated by nearby VFDs or heavy contactors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePanel Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen performing panel mounting, ensure the gasket is seated correctly against the cutout. In environments with high humidity or airborne contaminants, an airtight seal is critical to prevent moisture ingress into the internal LCD electronics, which can lead to \"ghosting\" or logic failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination Resistors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e080G0294\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the last node in your physical network chain, a 120 Ohm termination resistor must be installed across the CAN-H and CAN-L terminals to prevent signal reflection and data corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102418690411,"sku":"080G0294ÿ","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/080g0294-r4ls4543kwa.png?v=1776136974","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-080g0294-mmigrs2-canbus-control-panel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}