{"product_id":"danfoss-084z6048-mbt-5250-platinum-resistance-temperature-sensor","title":"Capteur de température à résistance platine MBT 5250 Danfoss 084Z6048","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e084Z6048 (084Z6046)\u003c\/strong\u003e\u003cspan\u003e is a heavy-duty platinum resistance temperature sensor (Pt100) engineered by Danfoss for demanding industrial and marine applications.\u003c\/span\u003e\u003cspan\u003e Designed as an insertion-type probe,\u003c\/span\u003e\u003cspan\u003e it excels in monitoring temperatures in cooling water,\u003c\/span\u003e\u003cspan\u003e lubrication oil,\u003c\/span\u003e\u003cspan\u003e and hydraulic systems where high vibration and aggressive media are constant factors.\u003c\/span\u003e\u003cspan\u003e The sensor's robust stainless steel construction and \u003c\/span\u003e\u003cstrong\u003eIP65\u003c\/strong\u003e\u003cspan\u003e enclosure rating ensure long-term stability in engine rooms,\u003c\/span\u003e\u003cspan\u003e offshore rigs,\u003c\/span\u003e\u003cspan\u003e and power plant environments.\u003c\/span\u003e\u003cspan\u003e By providing precise thermal feedback,\u003c\/span\u003e\u003cspan\u003e the \u003c\/span\u003e\u003cstrong\u003e084Z6048\u003c\/strong\u003e\u003cspan\u003e plays a critical role in preventing equipment overheating,\u003c\/span\u003e\u003cspan\u003e optimizing fuel efficiency,\u003c\/span\u003e\u003cspan\u003e and extending the service life of high-value rotating machinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis sensor utilizes a standardized Pt100 element,\u003c\/span\u003e\u003cspan\u003e ensuring high accuracy and interchangeability across global control systems.\u003c\/span\u003e\u003cspan\u003e The mechanical interface features a G 3\/4 inch male process connection according to ISO 228 standards,\u003c\/span\u003e\u003cspan\u003e fabricated entirely from high-grade stainless steel to resist corrosion.\u003c\/span\u003e\u003cspan\u003e The internal sensing element is designed to withstand ambient temperatures up to 90 deg C (194 deg F),\u003c\/span\u003e\u003cspan\u003e making it suitable for placement near heat-generating process equipment.\u003c\/span\u003e\u003cspan\u003e Its modular design allows for the sensing insert to be replaced without draining the process media,\u003c\/span\u003e\u003cspan\u003e significantly reducing maintenance complexity in pressurized systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e084Z6048 (Reference 084Z6046)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInsertion Temperature Sensor (Pt100)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProcess Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG 3\/4 (Male)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISO 228\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaterial (Wetted Parts)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Ambient Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 deg C (194 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensor Element\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatinum Resistance (Pt)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMarine, Industrial Hydraulics, Cooling Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the product description list both 084Z6048 and 084Z6046?\u003c\/strong\u003e\u003cspan\u003eIn the Danfoss catalog,\u003c\/span\u003e\u003cspan\u003e these numbers often refer to the same technical assembly or specific sub-components (such as the sensor head vs.\u003c\/span\u003e\u003cspan\u003e the complete unit).\u003c\/span\u003e\u003cspan\u003e The 084Z6048 is the commercial ordering code for the complete insertion sensor assembly as specified.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this sensor be used in high-vibration environments?\u003c\/strong\u003e\u003cspan\u003eYes,\u003c\/span\u003e\u003cspan\u003e the MBT series from Danfoss is specifically designed for marine \"Type Approval\" standards.\u003c\/span\u003e\u003cspan\u003e The internal wiring and sensing element are shock-mounted to withstand the constant vibrations found on large diesel engines and reciprocating compressors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the sensing element replaceable without removing the housing?\u003c\/strong\u003e\u003cspan\u003eDepending on the specific pocket (thermowell) configuration used with this G 3\/4 connection,\u003c\/span\u003e\u003cspan\u003e the MBT design typically allows the internal Pt100 insert to be swapped out while the process remains sealed,\u003c\/span\u003e\u003cspan\u003e minimizing system downtime.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeal Integrity:\u003c\/strong\u003e\u003cspan\u003e When installing the G 3\/4 male connection,\u003c\/span\u003e\u003cspan\u003e utilize a compatible copper or bonded seal washer to ensure a leak-proof interface.\u003c\/span\u003e\u003cspan\u003e Over-tightening can deform the stainless steel threads; always refer to the specific torque values for ISO 228 G-type threads in hydraulic applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImmersion Depth:\u003c\/strong\u003e\u003cspan\u003e To achieve accurate thermal readings,\u003c\/span\u003e\u003cspan\u003e ensure the sensor tip is immersed at least 6 to 10 times the diameter of the protection tube into the media flow.\u003c\/span\u003e\u003cspan\u003e In pipelines,\u003c\/span\u003e\u003cspan\u003e the tip should ideally reach the center of the pipe to avoid \"wall effect\" temperature lags.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring \u0026amp; Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e Since this is a Pt100 resistance-based sensor,\u003c\/span\u003e\u003cspan\u003e use 3-wire or 4-wire compensated cabling to eliminate the effect of lead-wire resistance over long distances.\u003c\/span\u003e\u003cspan\u003e Ensure the IP65 cable gland is tightened correctly to prevent moisture ingress from humid engine room environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102416494955,"sku":"084Z6048","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/084z6048-ooufdllrs1w.png?v=1776136991","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-084z6048-mbt-5250-platinum-resistance-temperature-sensor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}