{"product_id":"danfoss-131f6612-frequency-converter-vlt-automationdrive-fc-302","title":"Convertisseur de fréquence Danfoss 131F6612 VLT AutomationDrive FC 302","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 131F6612 (302P15KT5E20H1BGXXXXSXXXXAXBXCXXXXDX)\u003c\/strong\u003e is a high-performance \u003cstrong\u003e15 kW \/ 20 HP\u003c\/strong\u003e variable frequency drive built for rigorous industrial automation. As a primary component of the VLT AutomationDrive FC 302 series, this drive is engineered for high-dynamic performance in demanding applications such as textile machinery, packaging lines, and complex material handling systems. By utilizing advanced vector control, the \u003cstrong\u003e131F6612\u003c\/strong\u003e delivers precise speed and torque regulation, significantly reducing mechanical stress on drivetrains and optimizing throughput to prevent costly downtime in continuous production environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis drive is designed for robust three-phase operation across a wide voltage range of 380-500 VAC. The B3-frame hardware architecture provides a compact, chassis-mounted solution with an IP20 ingress protection rating, making it ideal for installation within standard industrial control cabinets. The unit features an integrated brake chopper, enabling efficient management of regenerative energy during high-frequency stop\/start cycles. Electromagnetic compatibility is ensured via the factory-installed RFI Class A1\/B (C1) filter, which minimizes harmonic distortion and interference with sensitive downstream electronics.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e131F6612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Type\u003c\/td\u003e\n\u003ctd\u003eVLT AutomationDrive FC 302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e15 kW \/ 20 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains Voltage\u003c\/td\u003e\n\u003ctd\u003e380 to 500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhases\u003c\/td\u003e\n\u003ctd\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP 20 (Chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRFI Filter\u003c\/td\u003e\n\u003ctd\u003eClass A1\/B (C1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake Chopper\u003c\/td\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eGraphical LCP (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e24.9 cm x 16.5 cm x 39.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e11.42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the advantages of the Graphical Local Control Panel (LCP) included with this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe graphical LCP provides a multi-line display that enables plain-text monitoring, menu-driven parameter setup, and real-time status diagnostics. This significantly reduces the learning curve for operators and accelerates the commissioning of complex automation routines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this drive suitable for high-dynamic braking applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the inclusion of an integrated brake chopper allows this unit to manage rapid deceleration phases. By connecting an appropriately sized external braking resistor, the drive can convert excess regenerative energy into heat, preventing DC-link overvoltage trips.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be used in environments with conductive dust?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific unit does not feature coated PCBs. In environments where conductive or corrosive dust is present, the drive must be installed in a sealed, climate-controlled enclosure to prevent short circuits and electronic degradation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the C1 RFI filter affect installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Class A1\/B (C1) filter allows the drive to comply with strict electromagnetic compatibility standards for use in commercial and light-industrial environments. For optimal performance, ensure that the motor cable is shielded and that the shield is properly bonded to the drive and motor ground points.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines and Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e The B3 frame size is optimized for density, but internal components generate significant heat at 15 kW. Ensure a minimum of 100 mm of clearance above and below the drive to facilitate proper airflow. If the control cabinet ambient temperature exceeds 40 deg C, forced-air cooling is mandatory to prevent thermal derating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e To minimize electromagnetic noise, always use shielded power cables for the motor. The shield should be terminated using a 360-degree conductive clamp to the drive’s ground terminal. Never route sensitive analog control signal wires alongside high-voltage power cables in the same conduit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoutine Servicing:\u003c\/strong\u003e Periodically check the tightness of the power and control terminal connections. Given the 11.42 kg weight, ensure the mounting backplate is structurally reinforced to support the vibration profiles typical of high-performance automation machinery.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102409613675,"sku":"131F6612","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131f6612-nrbzgfzdpf1.png?v=1776137008","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-131f6612-frequency-converter-vlt-automationdrive-fc-302","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}