{"product_id":"danfoss-131f9853-vlt-hvac-drive-fc-102","title":"Danfoss 131F9853 Variateur VLT HVAC FC-102","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 131F9853 (FC-102P18KT4E20)\u003c\/strong\u003e is a high-efficiency frequency converter specifically optimized for the VLT HVAC Drive FC-102 series. Engineered for building automation systems, this 18.5 kW (25 HP) drive excels in controlling pumps, fans, and compressors in commercial and industrial HVAC applications. By providing precise motor speed control, the 131F9853 significantly reduces energy consumption and mechanical wear on building infrastructure. Its integration into ventilation and cooling systems ensures consistent climate regulation, minimizing the risk of system-wide downtime and optimizing operational costs for facility management.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 131F9853 is built to facilitate seamless integration into modern HVAC infrastructures through robust hardware and software design:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrive Platform\u003c\/strong\u003e: VLT HVAC Drive FC-102, tailored for building management system requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Capacity\u003c\/strong\u003e: Rated for 18.5 kW (25 HP) motor applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Input\u003c\/strong\u003e: Configured for 380-480 VAC, three-phase mains supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: IP20 \/ Chassis design, intended for installation within climate-controlled electrical panels or cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency Focus\u003c\/strong\u003e: Features built-in intelligence to optimize HVAC motor performance, including automatic energy optimization (AEO) and advanced PID controllers for pressure and flow management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e131F9853\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e18.5 kW \/ 25 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains Voltage\u003c\/td\u003e\n\u003ctd\u003e380 - 480 VAC, 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e11.51 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this drive suitable for outdoor installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the IP20 enclosure is not protected against water spray or significant dust ingress. It must be installed inside a clean, dry, and ventilated electrical cabinet to ensure longevity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be integrated into a BACnet or Modbus building management system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the FC-102 series is specifically designed for seamless communication with HVAC-standard building management protocols, typically requiring an optional communication card if not pre-installed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical lead time for this component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 131F9853 typically ships within 1-10 working days, depending on current inventory levels and global distribution logistics.\u003c\/p\u003e\n\u003ch3\u003eEngineering Guidelines and Installation Best Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation Requirements\u003c\/strong\u003e: The 18.5 kW unit generates significant heat during operation. Install the drive in an enclosure with adequate forced-air cooling. Maintain a clearance of at least 200 mm above and below the unit to ensure unimpeded airflow across the heat sink.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Management\u003c\/strong\u003e: Use screened\/shielded cables for motor connections to minimize electromagnetic noise, which can interfere with sensitive building control sensors. Terminate the shield at both the drive and the motor ends using metal cable glands for the best EMC performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeriodic Maintenance\u003c\/strong\u003e: Regularly inspect the cooling fan at the base of the unit for dust accumulation. Given the typical HVAC environment, clogged fans can lead to premature thermal trips. Clean the heatsink fins periodically using low-pressure dry compressed air to maintain optimal thermal efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102381236587,"sku":"131F9853","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131f9853-45stojiy4kg.png?v=1776137010","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-131f9853-vlt-hvac-drive-fc-102","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}