{"product_id":"danfoss-131g1413-frequency-converter-vlt-hvac-drive-fc-102","title":"Convertisseur de fréquence Danfoss 131G1413 VLT HVAC Drive FC 102","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 131G1413 (FC-102P75KT4E66H2XGXXXXSXXXXAXBXCXXXXDX)\u003c\/strong\u003e is a high-performance \u003cstrong\u003e75 kW\u003c\/strong\u003e frequency converter engineered to deliver optimized process control for mission-critical HVAC applications. As a core member of the VLT HVAC Drive FC 102 series, this drive is designed to minimize lifecycle costs through advanced energy optimization and intelligent automation. Capable of controlling multiple high-efficiency permanent magnet motors in parallel, this drive ensures seamless integration into modern building management systems, effectively reducing operational overhead and ensuring compliance with stringent environmental regulations without the need for external cooling or oversized hardware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis 75 kW unit is designed for reliable three-phase operation. It features a robust, modular hardware architecture that eliminates the requirement for external control and conversion equipment by integrating specific functionality for pumps, fans, and compressors. The device includes a graphical Local Control Panel (LCP-102) for intuitive programming and a built-in energy meter compliant with NABERS standards. To ensure electromagnetic compatibility in commercial installations, the unit comes equipped with a factory-integrated RFI Class A2 filter. The drive also includes a Smart Logic Controller, which frequently negates the need for external PLC capacity, simplifying the control infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e131G1413\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Type\u003c\/td\u003e\n\u003ctd\u003eVLT HVAC Drive FC 102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains Voltage\u003c\/td\u003e\n\u003ctd\u003e380 to 480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhases\u003c\/td\u003e\n\u003ctd\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP 66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRFI Filter\u003c\/td\u003e\n\u003ctd\u003eClass A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Panel\u003c\/td\u003e\n\u003ctd\u003eLCP-102 Graphical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eModbus \u0026amp; BACnet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e6.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Automatic Energy Optimization (AEO) function work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AEO function continuously monitors the motor load and adjusts the magnetizing current to the absolute minimum required for the task. This results in an automatic 5-15 percent energy saving compared to standard VFD operation, particularly in partial-load fan and pump scenarios.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs external cooling required for this drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The FC 102 is designed for high-temperature resilience, allowing for full-load operation in ambient temperatures up to 50 deg C without derating, which avoids the need for expensive external cooling systems or over-sizing the drive hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this drive require external energy metering?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the built-in energy meter is NABERS-compliant, providing real-time power consumption data directly to the building management system, which reduces system complexity and installation costs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre standard HVAC communication protocols supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, both Modbus and BTL-listed BACnet are included free of charge. These protocols allow for quick and easy integration into existing BMS architectures, enabling the transfer of operational data points and setpoints with minimal setup time.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines and Best Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Compliance:\u003c\/strong\u003e Out-of-the-box compliance with IEC 61800-3 Category C1 is achieved by correctly bonding the motor cable to the motor terminal. Ensure that the motor cable shield is terminated using a 360-degree clamp at both the drive and the motor to maintain the required EMC integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning with Smart Start:\u003c\/strong\u003e Utilize the built-in Smart Start guide for the initial setup. This tool provides a step-by-step walkthrough in plain language, significantly reducing commissioning time and ensuring that all critical parameters are correctly aligned with your specific application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance of Uniform Interface:\u003c\/strong\u003e The VLT HVAC Drive FC 102 utilizes a unified interface across the 1.1 kW to 1400 kW power range. If your facility utilizes multiple drives of varying sizes, the programming logic remains consistent, allowing your maintenance team to manage the 75 kW unit with the same efficiency as smaller 3 kW models.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102409711979,"sku":"FC-102P75KT4E66H2XGXXXXSXXXXAXBXCXXXXDX","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FC-102P75KT4E66H2XGXXXXSXXXXAXBXCXXXXDX-bo3k514h0ox.png?v=1776137398","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-131g1413-frequency-converter-vlt-hvac-drive-fc-102","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}