{"product_id":"danfoss-132f0017-fc-051pk37t4e20h3xxcxxxsxxx-vlt-micro-drive","title":"Danfoss 132F0017 FC-051PK37T4E20H3XXCXXXSXXX VLT Micro Drive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 132F0017 (FC-051PK37T4E20H3XXCXXXSXXX)\u003c\/strong\u003e is a high-performance VLT Micro Drive engineered for versatile and space-constrained motor control applications. This compact drive is optimized for machinery integration, material handling systems, and light industrial automation, providing reliable frequency conversion for 0.37 kW (0.50 HP) three-phase motors. By offering precise speed regulation and energy optimization, this unit serves as a critical component in reducing mechanical stress and electrical demand in OEM equipment and process control environments. Its small-form-factor design ensures efficient use of cabinet space without sacrificing performance or thermal robustness.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e132F0017\u003c\/strong\u003e follows a specific modular designators system for the VLT Micro Drive FC-051 series:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFC-051:\u003c\/strong\u003e Defines the series as the VLT Micro Drive platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePK37:\u003c\/strong\u003e Indicates the power rating of 0.37 kW \/ 0.50 HP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eT4:\u003c\/strong\u003e Specifies three-phase 380 - 480 VAC mains voltage compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE20:\u003c\/strong\u003e Denotes an IP20-rated enclosure for chassis-mount applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eH3:\u003c\/strong\u003e Incorporates an integrated RFI Class A1\/B (C1) filter for EMC compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC:\u003c\/strong\u003e Signifies that the internal printed circuit boards (PCB) are coated, providing enhanced protection against dust, humidity, and corrosive atmospheric conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eXX\/SXXX:\u003c\/strong\u003e Represents standard hardware and software configurations without specialized options or brake choppers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-051PK37T4E20H3XXCXXXSXXX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e0.37 kW \/ 0.50 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e380 - 480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e1.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14.8 cm x 7 cm x 15 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e5 (0 - 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 - 200 Hz (VVC+); 0 - 400 Hz (U\/f)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this drive suitable for use in dusty or slightly corrosive industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the inclusion of the \"C\" suffix indicates that the internal PCBs are coated, which significantly improves resistance against harsh ambient conditions compared to standard, uncoated models.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 132F0017 model require an external control panel (LCP) for basic operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this unit is shipped without a factory-mounted Local Control Panel (LCP). However, it can be configured via serial communication or by adding an optional snap-on LCP if local manual control and monitoring are required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be used for safety-rated stop applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this specific configuration (indicated by the \"X\" in the Safe Stop position of the part number) does not include the integrated safe stop function. For applications requiring functional safety, a model with the appropriate safe stop hardware must be selected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the drive cooled during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit utilizes forced convection cooling. Ensure that air can flow freely through the heat sink fins and that there is adequate space above and below the drive to prevent thermal throttling.\u003c\/p\u003e\n\u003ch3\u003eEngineering Guidelines and Best Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting and Clearance:\u003c\/strong\u003e To maintain optimal thermal performance, mount the drive vertically on a flat surface. Maintain a minimum clearance of 100 mm of unobstructed space above and below the device to ensure proper heat dissipation and avoid premature thermal failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Standards:\u003c\/strong\u003e Use properly rated power cables with appropriate shielding to prevent radiated noise. Keep motor cables as short as possible. Connect the cable shield to the chassis ground terminal using a 360-degree conductive clamp to effectively mitigate electromagnetic interference (EMI) according to the integrated RFI filter specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e While the IP20 rating is suitable for most electrical cabinets, it does not protect against liquid ingress or conductive dust. Always install the unit in an appropriate NEMA or IP-rated enclosure if the installation site environment exceeds standard industrial pollution levels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102408892779,"sku":"132F0017","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/132f0017-bbkubu42jxe.png?v=1776137028","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-132f0017-fc-051pk37t4e20h3xxcxxxsxxx-vlt-micro-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}