{"product_id":"danfoss-132f0020-vlt-micro-drive-fc-051-frequency-inverter","title":"Danfoss 132F0020 Variateur VLT Micro Drive FC-051","description":"\u003ch3\u003eTechnical Profile and Dynamic Motor Control\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e132F0020 (132F0020)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty industrial frequency inverter from the Danfoss VLT Micro Drive FC-051 series. Engineered for space-optimized control cabinets, this compact variable speed drive provides precise, energy-efficient control of three-phase asynchronous AC motors. It is widely used in material handling conveyors, industrial fan ventilation networks, automated commercial pumping systems, and specialized OEM machinery lines.\u003c\/p\u003e\n\u003cp\u003eOperating with a rated capacity of 1.5 kW (2.0 HP), the drive utilizes advanced VVC+ (Voltage Vector Control Plus) topology to maintain exceptional motor shaft torque performance and stable speed regulation even under fluctuating load profiles. By integrating localized power-loss ride-through capabilities, an automated motor tuning wizard, and continuous electronic thermal protection, the drive minimizes system wear, prevents mechanical stress, and ensures consistent uptime in fast-paced production lines.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown and Structural Blueprint\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFC-051:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the core VLT Micro Drive series platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eP1K5:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates the 1.5 kW (2.0 HP) nominal electrical output power rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eT4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEstablishes the incoming mains electrical supply configuration as Three-phase 380-480 VAC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eE20:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDenotes the physical hardware enclosure class as IP20 \/ Chassis, intended for protective cabinet mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eH3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfirms the integration of a high-performance RFI filter matching Class A1\/B (C1) electromagnetic emission standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eB:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHighlights the inclusion of an internal dynamic brake chopper module to handle regenerative energy from overhauling loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eC:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies that the internal printed circuit boards (PCBs) feature a conformal coating protection layer to resist airborne moisture and chemical particulate contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eComprehensive Engineering Performance Data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDocumented Technical Specification Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-051P1K5T4E20H3BXCXXXSXXX (132F0020)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDenmark\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.7 A continuous rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Supply Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 100% of incoming mains supply voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Frequency Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 200 Hz (VVC+ Vector Mode) \/ 0 to 400 Hz (Scalar U\/f Mode)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Control Interfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Programmable digital inputs (0 to 24 VDC logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePulse Reference Tracking\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Pulse input interface supporting 20 to 5000 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Interfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Analog inputs (Software configurable for voltage or current loops)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCooling Topology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated back-mounted heatsink with forced convection airflow\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e168 x 75 x 176 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Shipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Field Operations and Support FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this drive package include a local control\u003cspan\u003e \u003c\/span\u003einterface panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The \"X\" configuration suffix signifies that the standalone 132F0020 drive does not ship with a Local Control Panel (LCP) pre-installed. For programming, field tuning, or real-time diagnostic tracking, you must order either the VLT Control Panel LCP 11 (without potentiometer) or LCP 12 (with integrated potentiometer) as a separate accessory line item.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific operational protection does the internal brake chopper provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated brake chopper handles energy fed back from the motor during rapid deceleration cycles or when braking high-inertia loads. By routing this regenerative power out through an externally connected power resistor, the drive prevents overvoltage trips and maintains precise deceleration ramping profiles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does a compact 1.5 kW frequency inverter carry a 5.0 kg shipping weight?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 5.0 kg shipping mass reflects ruggedized international transit packaging. Because heavy-duty variable frequency drives contain large, heavy aluminum cooling heatsinks, structural capacitors, and sensitive digital processors, the unit is packed inside heavy anti-static wrap, thick molded shock inserts, and thick exterior cardboard to protect against drop damage and mechanical vibration during global transport.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCritical Installation Logistics and Commissioning Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSide-by-Side Mounting and Thermal Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact chassis design of the FC-051 series supports true side-by-side vertical mounting on standard DIN rails to maximize panel space. However, to maintain adequate natural convection currents, you must preserve a minimum unobstructed vertical clearance of 100 mm directly above and below the drive's cooling fan assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput and Output Separated Conduit Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the incoming AC mains supply cables (L1, L2, L3) and the output motor power lines (U, V, W) through completely separate industrial conduits. Never run motor power lines in parallel alongside low-voltage control signals, digital input wires, or communication lines to avoid electromagnetic crosstalk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Cable Shielding and Grounding Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways connect the drive to the motor using high-quality, continuous copper-braid shielded cable. Terminate the shield surface completely at both ends using low-impedance metal grounding clamps—one at the drive enclosure chassis shield plate and the other directly at the motor terminal box—to suppress high-frequency radio frequency interference (RFI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102412562795,"sku":"132F0020","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/132f0020-0xp5caafzod.png?v=1776137029","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-132f0020-vlt-micro-drive-fc-051-frequency-inverter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}