{"product_id":"danfoss-134f2975-vlt-automationdrive-fc-360-frequency-converter","title":"Danfoss 134F2975 VLT AutomationDrive FC-360 Convertisseur de fréquence","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e134F2975 (FC-360H2K2T4E20H2BXCDXXSXXXXAXBX)\u003c\/strong\u003e is a robust frequency converter from the Danfoss VLT AutomationDrive FC-360 series, precision-engineered for high-load industrial applications. This drive, rated for 2.2 kW (3.0 HP), serves as a critical component in automation systems requiring high torque stability and precise motor control, such as industrial conveyors, mixers, and processing machinery. By integrating advanced drive technology, the \u003cstrong\u003e134F2975\u003c\/strong\u003e effectively reduces mechanical strain on connected hardware and optimizes energy expenditure. Its coated PCB design ensures long-term operational integrity even in environments where dust or humidity could jeopardize sensitive electronics, making it an essential asset for minimizing unscheduled maintenance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFC-360\u003c\/strong\u003e architecture is built for demanding production lines that necessitate high reliability and rapid control response. This unit features an integrated brake chopper, facilitating controlled deceleration for high-inertia loads. Configured with an IP20 enclosure, the drive is optimized for panel mounting, providing space-efficient integration. It is equipped with Loadsharing capability, allowing for energy management between multiple drive units to maximize overall system efficiency. The drive supports a 380-480 VAC three-phase input, ensuring broad compatibility with standard industrial power grids. While this unit is supplied without a local display, its standard control card allows for seamless integration into higher-level PLC or DCS networks for remote monitoring and parameter management.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e134F2975\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eVLT AutomationDrive FC-360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003ePower Rating\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e2.2 kW \/ 3.0 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eOverload\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eHigh Overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003ePhases\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eMains Voltage\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e380 - 480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eRFI Filter\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eClass A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eBrake Chopper\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003ePCB Coating\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eCoated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e2.64 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the integrated Brake Chopper in this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe brake chopper allows the drive to dissipate energy generated by the motor during deceleration or braking. This is crucial for applications involving high-inertia loads, preventing DC-link overvoltage faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 134F2975 be monitored without a local display?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Since the unit lacks an integrated display, all monitoring and configuration must be performed through a remote terminal connection or by interfacing the drive via fieldbus with your primary control system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Loadsharing feature work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Loadsharing (D option) allows the DC-bus of the drive to be connected to other compatible drives. This facilitates energy exchange between drives in a system, where one drive acting as a generator can provide power to another drive acting as a motor.\u003c\/p\u003e\n\u003ch3\u003eEngineering Best Practices and Installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e Ensure the drive is installed in an environment where ambient temperature does not exceed the manufacturer's specified limits. Maintain a minimum vertical clearance of 100 mm above and below the unit to facilitate the airflow required for the internal heat sinks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e To minimize radiated emissions and ensure compliance with the RFI Class A2 standard, always use shielded motor cables. The shield must be connected 360 degrees to the chassis using conductive cable clamps at both the drive and the motor terminal box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Selection:\u003c\/strong\u003e For the 380-480 VAC input, ensure that the supply cables are sized according to local electrical codes for the specified power rating. Use appropriate ferrules for terminal connections to ensure a secure, low-resistance mechanical contact.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102410826091,"sku":"134F2975","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/134f2975-dxm2maqrlpx.png?v=1776137055","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-134f2975-vlt-automationdrive-fc-360-frequency-converter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}