{"product_id":"danfoss-134f2976-fc-360h3k0t4e20h2bxcdxxsxxxxaxbx-vlt-automationdrive","title":"Danfoss 134F2976 FC-360H3K0T4E20H2BXCDXXSXXXXAXBX VLT AutomationDrive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 134F2976 (FC-360H3K0T4E20H3K0T4E20H2BXCDXXSXXXXAXBX)\u003c\/strong\u003e VLT AutomationDrive is a high-performance frequency converter designed for demanding industrial process control. Optimized for applications such as pump systems, centrifuges, and automated conveyor lines, this drive minimizes system downtime by providing precise motor torque and speed regulation. Built with a robust IP20 chassis and conformal-coated PCB, it ensures reliable operation in manufacturing environments where environmental contaminants are present. The unit supports critical industrial infrastructure by facilitating energy-efficient operation and reducing mechanical stress on motor-driven systems during start-up and transient load conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e134F2976\u003c\/strong\u003e is configured for high-overload capability, specifically rated for a 3.0 kW (4.0 HP) power output within a 380-480 VAC three-phase network. It features an integrated RFI Class A2 filter for electromagnetic compatibility and a built-in brake chopper to handle regenerative energy during rapid deceleration. The hardware includes a DC load-sharing (Mains Option D) capability, allowing for energy management in multi-drive systems. Designed for flexible integration, this unit is supplied without a local display, utilizing a standard control card that supports the latest Danfoss standard software release, ensuring seamless integration into existing PLC-based automation architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e134F2976\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eVLT AutomationDrive FC-360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003ePower Rating\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e3.0 kW (4.0 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eMains Voltage\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e380 - 480 VAC (3-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eEnclosure Class\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eRFI Filter\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eClass A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003ePCB Coating\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eCoated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eMains Option\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eLoadsharing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eBrake Chopper\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e4.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of the load-sharing feature in this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe load-sharing option allows the DC bus of the drive to be connected to other drives in the system, enabling the redistribution of energy during braking cycles and improving overall energy efficiency across the factory floor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be used in high-vibration areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the VLT AutomationDrive FC-360 is built to handle standard industrial vibration levels; however, ensure the chassis is mounted to a rigid, grounded steel backplane to prevent resonance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs a display required for troubleshooting or parameter adjustment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model is supplied without an LCP (Local Control Panel). While operational control is managed via the terminal inputs, an external LCP or PC-based connection is required for monitoring, diagnostics, and parameter setting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the conformal coating sufficient for chemical exposure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"C\" code indicates the internal circuitry is coated to meet class 3C3 requirements (IEC 60721-3-3), offering significant protection against corrosive gases and humidity, common in process industries like chemical production or food processing.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoadsharing Safety:\u003c\/strong\u003e When utilizing the Loadsharing (Mains Option D) functionality, ensure all connected drives share a common DC bus potential. Always perform a ground integrity check on the entire DC bus circuit before applying power to prevent catastrophic short-circuit failures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e The 134F2976 generates heat during operation. Ensure the control cabinet is equipped with filtered forced-air cooling. Maintain a minimum clearance of 100 mm at the top and bottom of the drive to ensure the internal airflow paths are unobstructed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding for EMC:\u003c\/strong\u003e To maintain the efficacy of the integrated Class A2 RFI filter, connect the motor cable screen to the metal mounting plate using a 360-degree conductive clamp. This is critical for preventing high-frequency noise from affecting nearby instrumentation and PLC signals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102411579755,"sku":"134F2976","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/134f2976-ejotkocukpf.png?v=1776137055","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-134f2976-fc-360h3k0t4e20h2bxcdxxsxxxxaxbx-vlt-automationdrive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}