{"product_id":"danfoss-134f2985-fc-360h37kt4e20h2xxcdxxsxxxxaxbx-frequency-converter","title":"Danfoss 134F2985 Convertisseur de fréquence FC-360H37KT4E20H2XXCDXXSXXXXAXBX","description":"\u003cp\u003eThe \u003cstrong\u003e134F2985\u003c\/strong\u003e is a high-performance \u003cstrong\u003eFC-360H37KT4E20H2XXCDXXSXXXXAXBX Frequency Converter\u003c\/strong\u003e from the Danfoss VLT AutomationDrive FC 360 series. This unit is designed for demanding industrial motor control applications, providing robust torque and speed regulation for 37 kW (50 HP) three-phase AC motors. It features a compact IP20 chassis design and includes coated PCBs to enhance reliability in harsh industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for high overload performance in heavy-duty applications\u003c\/li\u003e\n\u003cli\u003eIntegrated RFI Class A2 filter for electromagnetic compatibility\u003c\/li\u003e\n\u003cli\u003eConformal coated PCB for increased durability against environmental factors\u003c\/li\u003e\n\u003cli\u003eLoadsharing functionality for multi-drive system configurations\u003c\/li\u003e\n\u003cli\u003eStandard control card architecture for reliable system integration\u003c\/li\u003e\n\u003cli\u003eDesigned for 380-480VAC three-phase input power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePumping and ventilation systems\u003c\/li\u003e\n\u003cli\u003eMaterial handling and conveyor drives\u003c\/li\u003e\n\u003cli\u003eIndustrial processing machinery\u003c\/li\u003e\n\u003cli\u003eExtruders and mixers\u003c\/li\u003e\n\u003cli\u003eGeneral motor control in manufacturing lines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e134F2985\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-360H37KT4E20H2XXCDXXSXXXXAXBX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Group\u003c\/td\u003e\n\u003ctd\u003eVLT AutomationDrive FC 360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e37 KW \/ 50 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input\u003c\/td\u003e\n\u003ctd\u003e380-480VAC (Three Phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRFI Filter\u003c\/td\u003e\n\u003ctd\u003eClass A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eCoated PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains Option\u003c\/td\u003e\n\u003ctd\u003eLoadsharing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e24.37 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e26 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the converter in a vertical position on a flat surface to facilitate optimal cooling airflow through the heat sink.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e Ensure the operating environment is within the specified temperature limits. The coated PCB provides protection, but avoid direct exposure to extreme dust, moisture, or corrosive gases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Maintain sufficient clearance above and below the unit to allow for heat dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect power and control lines according to the terminal assignments in the official manual. Use shielded cables for control signals to prevent interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify that the chassis is securely grounded to the system protective earth to ensure safe operation and reduce EMI\/RFI emission.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102352662891,"sku":"134F2985","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/134f2985-gjuhcfese4c.png?v=1776137062","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-134f2985-fc-360h37kt4e20h2xxcdxxsxxxxaxbx-frequency-converter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}