{"product_id":"danfoss-134f3014-frequency-converter-vlt-automationdrive-fc-360","title":"Convertisseur de fréquence Danfoss 134F3014 VLT AutomationDrive FC 360","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss 134F3014 (FC-360H3K0T4E20H2BXCDXXSXXXXALBX)\u003c\/strong\u003e is a high-performance variable frequency drive engineered for demanding industrial automation tasks. As a flagship model in the VLT AutomationDrive FC 360 series, this \u003cstrong\u003e3.0 kW \/ 4.0 HP\u003c\/strong\u003e unit is designed to handle high-overload applications, including heavy-duty conveyors, mixers, and industrial extruders. By integrating advanced motor control algorithms and a high-speed ProfiNet interface, the \u003cstrong\u003e134F3014\u003c\/strong\u003e enables seamless real-time synchronization within complex production lines, significantly reducing system latency and preventing costly unplanned downtime in high-throughput manufacturing environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis drive is built for three-phase 380-480 VAC power systems and features a robust hardware architecture optimized for reliability. The unit includes an integrated brake chopper, facilitating precise control during rapid deceleration cycles. The internal printed circuit boards (PCBs) feature a conformal coating, providing superior protection against humidity and conductive dust. Equipped with a load-sharing terminal and a ProfiNet-capable control card, this drive allows for flexible energy management and easy integration into industrial Ethernet-based control networks, ensuring operational efficiency across diverse automation platforms.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e134F3014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Type\u003c\/td\u003e\n\u003ctd\u003eVLT AutomationDrive FC 360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e3.0 kW \/ 4.0 HP (High Overload)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains Voltage\u003c\/td\u003e\n\u003ctd\u003e380 to 480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhases\u003c\/td\u003e\n\u003ctd\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRFI Filter\u003c\/td\u003e\n\u003ctd\u003eClass A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eProfiNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake Chopper\u003c\/td\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e4.09 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of the ProfiNet interface on this drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated ProfiNet card allows for high-speed, deterministic data exchange between the drive and the PLC. This is critical for applications requiring precise motion synchronization, advanced diagnostic monitoring, and fast parameter configuration over industrial Ethernet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be used for applications requiring frequent braking?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 134F3014 includes a built-in brake chopper. By adding an external braking resistor, the drive can effectively dissipate the regenerative energy generated during rapid motor stops, preventing overvoltage trips and enabling faster machine cycle times.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the PCB coated in this specific model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe factory-applied conformal coating is essential for longevity in industrial settings. It prevents the formation of micro-corrosion on electrical components caused by ambient moisture, airborne contaminants, or chemical vapors, ensuring stable performance over the drive's service life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this model provided with a local control panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this unit is supplied without a display or blind cover. If manual monitoring or local parameter adjustment is required, an external Control Panel must be acquired and installed on the front interface.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines and Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Due to the high-overload capability of this 3.0 kW drive, internal heat generation is significant during peak performance. Ensure the installation cabinet is properly ventilated, and maintain a minimum of 150 mm of vertical clearance to ensure that cooling air can effectively pass through the heat sink.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfiNet Wiring:\u003c\/strong\u003e Use shielded Cat5e or Cat6 Industrial Ethernet cabling for the ProfiNet connection. Ensure the cable is routed away from high-voltage power lines to prevent electromagnetic coupling, which could disrupt communication packets and lead to \"Bus Off\" errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains Load Sharing:\u003c\/strong\u003e This unit supports load sharing via the DC-bus terminals. When configuring this feature, ensure that all paralleled drives are utilizing the same DC-bus voltage levels and that fast-acting fuses are installed in each DC-link path to isolate potential faults in individual units.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102409843051,"sku":"134F3014","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/134f3014-pufcj44a2yq.png?v=1776137070","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-134f3014-frequency-converter-vlt-automationdrive-fc-360","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}