{"product_id":"danfoss-cpce-15-034n0084-hot-gas-bypass-regulator","title":"DANFOSS CPCE 15 034N0084 Régulateur de dérivation gaz chaud","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e034N0084 (034N0084)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision hot gas bypass regulator, designated as Type CPCE 15, manufactured by Danfoss for industrial and commercial refrigeration systems. This valve is engineered to provide capacity regulation by bypassing hot gas from the high-pressure side of the system to the low-pressure side, typically between the expansion valve and the evaporator. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e034N0084\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis critical for maintaining a minimum evaporator pressure and preventing compressor short-cycling during low-load conditions. By ensuring a constant suction pressure, this regulator protects the compressor from liquid slugging and stabilizes the cooling performance in applications such as chillers, clean rooms, and food processing plants, even when the thermal load fluctuates significantly.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe CPCE 15 series is optimized for high-capacity performance and long-term mechanical stability in complex refrigerant circuits:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Balanced Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe regulator utilizes a pressure-balanced architecture that ensures accurate regulation regardless of fluctuations in the condensing pressure (high side).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eActuator System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a 13.5 mm actuator system designed for rapid response to pressure changes, providing immediate compensation to maintain the setpoint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to operate in ambient temperatures ranging from -40 to 50 Celsius, making it suitable for both outdoor installations and sub-zero mechanical rooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Pressure Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a maximum working pressure of 18 bar (approx. 261 psig), the unit is compatible with a wide range of standard high-pressure refrigerants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegration Synergy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for use in conjunction with a liquid-gas mixer (LG) to ensure proper mixing of the bypassed hot gas and the liquid refrigerant before entry into the evaporator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCPCE 15\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e034N0084\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHot Gas Bypass Regulator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eActuator System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Working Pressure (MWP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 bar (approx. 261 psig)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 50 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Ambient Temp (F)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140 deg F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the CPCE 15 prevent compressor damage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen the cooling load drops, the suction pressure normally falls. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e034N0084\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esenses this drop and opens to bypass hot gas into the low-pressure side. This keeps the suction pressure above a pre-defined limit, ensuring the compressor does not operate below its minimum rated pressure and preventing oil return issues or overheating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is the ideal installation point for the CPCE 15?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe regulator should be installed in a bypass line between the compressor discharge line and the distributor between the expansion valve and the evaporator. For the most efficient operation and to prevent evaporator icing, it should be paired with a Danfoss LG liquid-gas mixer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this regulator compatible with modern high-pressure refrigerants?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CPCE 15 is designed for a maximum working pressure of 18 bar. While it is compatible with many common refrigerants, always verify your specific system's peak discharge pressures to ensure they do not exceed the 18 bar limit during high-ambient operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePiping and Oil Return:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the bypass line, always ensure the piping is designed to allow oil to return to the compressor. The bypass line should ideally be taken from the top of the discharge line to prevent liquid refrigerant or oil from trapping in the regulator during standstill periods.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Balancing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring commissioning, adjust the CPCE 15 setpoint slowly while monitoring the suction pressure gauge. The valve should be set to open just above the minimum suction pressure required by the compressor manufacturer or the point where evaporator icing begins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough the unit is rated for 50 Celsius ambient, the hot gas passing through the valve can reach significantly higher temperatures. Ensure that nearby sensitive electronics or plastic components are shielded from the radiant heat of the bypass piping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102417772907,"sku":"034N0084","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/034n0084-xpqkwz3drzy.png?v=1776136893","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-cpce-15-034n0084-hot-gas-bypass-regulator","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}