{"product_id":"danfoss-fc-302p37kt5p55h2xgcxxxsxxxxa4bxcxxxxd0-vlt-automationdrive","title":"Danfoss FC-302P37KT5P55H2XGCXXXSXXXXA4BXCXXXXD0 Variateur VLT AutomationDrive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss FC-302P37KT5P55H2XGCXXXSXXXXA4BXCXXXXD0\u003c\/strong\u003e is a highly sophisticated, advanced version of the VLT AutomationDrive. Engineered for high-performance variable speed control, this drive supports both asynchronous and permanent magnet motors, making it a cornerstone for complex automation tasks. Rated for \u003cstrong\u003e37 kW\u003c\/strong\u003e and capable of handling high-voltage inputs (3-phase 525-690V), it is specifically designed for industrial environments that require precise motion control, robust system integration, and maximum uptime in demanding applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis unit is part of the advanced \u003cstrong\u003eFC-302\u003c\/strong\u003e series, featuring a modular architecture that allows for extensive customization via fieldbus and I\/O options.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Control:\u003c\/strong\u003e As a 302-series drive, it offers superior dynamic response and extended safety functions compared to the 301 series, ideal for high-precision manufacturing processes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Hardening:\u003c\/strong\u003e The inclusion of conformal coating (C) on all PCBs (Class 3C3) provides exceptional protection against corrosive gases, moisture, and dust, ensuring the drive operates reliably in harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Equipped with the \u003cstrong\u003eVLT® DeviceNet MCA 104\u003c\/strong\u003e fieldbus card (A4), this drive integrates seamlessly into DeviceNet industrial automation networks for centralized control and diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup Power:\u003c\/strong\u003e Features the \u003cstrong\u003eMCB 107\u003c\/strong\u003e (D0) 24V DC supply option, allowing the control electronics to remain powered even when main AC power is lost. This is critical for maintaining communication with the PLC and keeping data logs alive during outages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser Interface:\u003c\/strong\u003e Includes the Graphical Local Control Panel (\u003cstrong\u003eLCP-102\u003c\/strong\u003e), which provides intuitive, multi-language navigation, graphing capabilities, and easy status monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-302P37KT5P55H2XGCXXXSXXXXA4BXCXXXXD0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e37 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e3-Phase 525 - 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLCP Display\u003c\/td\u003e\n\u003ctd\u003eGraphical (LCP-102)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eConformal (Class 3C3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldbus\u003c\/td\u003e\n\u003ctd\u003eDeviceNet MCA 104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Backup\u003c\/td\u003e\n\u003ctd\u003eMCB 107 (24V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e45 kg (Shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of the MCB 107 24V DC supply option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MCB 107 ensures that the drive’s control card remains active during main power interruptions. This allows your PLC or BMS (Building Management System) to maintain a communication link with the drive, preventing communication timeout faults and allowing the system to log the reason for the power failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is an IP55 enclosure significant for this drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn IP55 rating indicates the drive is protected against dust ingress and low-pressure water jets from any direction. This allows the drive to be mounted in more exposed industrial areas where a standard IP20 chassis would require a costly, sealed electrical cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Graphical LCP-102 improve commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe graphical display allows for real-time trending (graphing) of parameters like motor current or frequency, making it significantly easier to diagnose process anomalies or tune performance compared to a standard numeric-only display.\u003c\/p\u003e\n\u003ch3\u003eEngineering Guidelines and Best Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Because this drive operates at high voltages and incorporates complex fieldbus communications, use high-quality shielded cables. Terminate shields with 360-degree conductive clamps at both ends to ensure high-frequency noise does not corrupt the DeviceNet communication loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Despite the IP55 rating, ensure that the drive has sufficient airflow for the heatsink. If operating at full load in a confined space, supplemental cooling may be required to prevent the drive from derating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeviceNet Termination:\u003c\/strong\u003e When commissioning the DeviceNet MCA 104 module, ensure the bus is terminated with the correct 121-ohm resistors at both ends of the trunk line to maintain communication signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102382088555,"sku":"FC-302P37KT5P55H2XGCXXXSXXXXA4BXCXXXXD0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FC-302P37KT5P55H2XGCXXXSXXXXA4BXCXXXXD0-ge2uamp5mil.png?v=1776137403","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-fc-302p37kt5p55h2xgcxxxsxxxxa4bxcxxxxd0-vlt-automationdrive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}