{"product_id":"danfoss-ic2-30-frequency-converter-132l6108-air-cooled-vfd","title":"Danfoss iC2-30 Variateur de fréquence 132L6108 refroidi par air","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e132L6108 (132L6108)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Danfoss iC2-30 series frequency converter engineered for precise motor control in compact industrial environments. Designed as a reliable successor in the micro-drive category, this air-cooled unit optimizes energy efficiency for single-phase applications ranging from 200 to 240 VAC. In critical sectors such as wastewater treatment, HVAC systems, and food processing, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e132L6108\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary controller for pumps and fans, significantly reducing mechanical stress and preventing unplanned downtime through its robust power electronics architecture. Its streamlined interface and high torque capabilities ensure seamless integration into automated production lines where space and thermal management are paramount.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model code\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC2-30FA1N02-06A8E20F4+ACXX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a specific logical structure defining its hardware capabilities:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIC2-30\u003c\/strong\u003e: Identifies the iC2-30 series product group.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFA\u003c\/strong\u003e: Indicates a Frequency Converter with Air Cooled thermal management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1N\u003c\/strong\u003e: Specifies Single-phase input configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Designates the Mains Voltage range of 200-240 VAC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06A8\u003c\/strong\u003e: Represents the rated output current of 6.8 A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eE20\u003c\/strong\u003e: Protection rating of IP20 \/ Open Type, suitable for cabinet mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eF4\u003c\/strong\u003e: Integrated EMC filter meeting C4 category standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e+ACXX\u003c\/strong\u003e: Indicates the absence of an integrated brake chopper.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e132L6108\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eiC2-30\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDenmark \/ China (Batch Dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200-240 VAC (Single-phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.8 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Open Type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eForced Air Cooling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 50 deg C (with derating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.275 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the iC2-30 handle electromagnetic interference in industrial grids?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 132L6108 includes a built-in F4 category EMC filter. While this provides standard protection, for environments requiring C1 or C2 compliance (residential or light industrial), additional external filtering may be necessary to prevent signal noise on sensitive instrumentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this model be used for vertical lifting applications without a brake chopper?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This specific variant (+ACXX) lacks an integrated brake chopper. For applications involving regenerative braking or high-inertia loads like cranes or vertical conveyors, a model with an integrated chopper or an external regenerative unit is required to prevent over-voltage trips.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary mounting requirements for the IP20 chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IP20 rating requires the unit to be installed within a protective control cabinet. It supports side-by-side mounting to save rail space, provided that vertical clearance is maintained for the air-cooling intake and exhaust.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management \u0026amp; Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure the longevity of the 6.8 A power stage, maintain a minimum vertical clearance of 100 mm above and below the unit. Even though the iC2-30 supports side-by-side mounting, in high-ambient environments (above 40 deg C), a 5 mm gap between drives is recommended to prevent localized heat pockets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring \u0026amp; Grounding Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways utilize shielded motor cables to minimize RFI. Ensure the shield is grounded at both the frequency converter and the motor end using metal saddles (360-degree grounding) rather than \"pigtails,\" which act as antennas for high-frequency noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOverload Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit provides electronic motor overload protection. Ensure the motor nameplate data (Current, RPM, Voltage) is accurately commissioned into the drive parameters to prevent stator overheating during low-speed, high-torque operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102416888171,"sku":"132L6108","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/132l6108-q2czzm43zsq.png?v=1776137039","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-ic2-30-frequency-converter-132l6108-air-cooled-vfd","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}