{"product_id":"danfoss-kps81-060l310666-pressure-switch-and-thermostat","title":"Interrupteur de pression et thermostat Danfoss KPS81 060L310666","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDanfoss KPS81 060L310666\u003c\/strong\u003e is a robust \u003cstrong\u003ePressure Switch and Thermostat\u003c\/strong\u003e designed for demanding industrial control and monitoring applications. As part of the KPS series, this unit provides precise temperature regulation with an adjustable setting range of 60 to 150 degC. It is specifically engineered to operate in environments where high accuracy and durability are critical for safety and operational efficiency.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003ePressure Switch and Thermostat\u003c\/strong\u003e utilizes a capillary tube length of 2 meters to allow for flexible installation options. It features an adjustable mechanical differential ranging from 5 to 25 degC, enabling users to fine-tune the switching behavior to suit specific process requirements. The device supports a maximum sensor temperature of 250 degC, making it suitable for high-temperature media monitoring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable setting range: 60 to 150 degC\u003c\/li\u003e\n\u003cli\u003eAdjustable mechanical differential: 5 to 25 degC\u003c\/li\u003e\n\u003cli\u003eHigh temperature tolerance with a max sensor temperature of 250 degC\u003c\/li\u003e\n\u003cli\u003eCapillary tube length: 2 m\u003c\/li\u003e\n\u003cli\u003eCompatible with various sensor pocket lengths (65 mm, 75 mm, 110 mm, 160 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial heating and cooling systems\u003c\/li\u003e\n\u003cli\u003eThermal process control\u003c\/li\u003e\n\u003cli\u003ePower plant auxiliary systems\u003c\/li\u003e\n\u003cli\u003eMachinery and heavy industrial equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKPS81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCode No.\u003c\/td\u003e\n\u003ctd\u003e060L310666\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePressure Switch and Thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting Range\u003c\/td\u003e\n\u003ctd\u003e60 to 150 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Differential\u003c\/td\u003e\n\u003ctd\u003e5 to 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Sensor Temperature\u003c\/td\u003e\n\u003ctd\u003e250 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapillary Tube Length\u003c\/td\u003e\n\u003ctd\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Sensor Pockets\u003c\/td\u003e\n\u003ctd\u003e65 mm, 75 mm, 110 mm, 160 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the unit is mounted in a stable position free from excessive mechanical vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Installation:\u003c\/strong\u003e Select the appropriate sensor pocket (65, 75, 110, or 160 mm) based on the application requirements to ensure accurate thermal contact with the medium.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapillary Management:\u003c\/strong\u003e Handle the 2-meter capillary tube with care during installation to avoid kinks or sharp bends, which can affect the accuracy of the temperature sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Adjust the differential setting within the specified 5 to 25 degC range according to the specific process setpoint requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102306623851,"sku":"KPS81 060L310666","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/kps81060l310666-wc505l30svp.png?v=1776137782","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-kps81-060l310666-pressure-switch-and-thermostat","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}