{"product_id":"danfoss-vlt-automationdrive-fc-302p5k5t5e20h2xgc-5-5kw","title":"Variateur Danfoss VLT AutomationDrive FC-302P5K5T5E20H2XGC 5,5 kW","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-302P5K5T5E20H2XGC (131B0151)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance VLT® AutomationDrive FC 302 series frequency inverter, specifically engineered by Danfoss for advanced industrial motor control applications. Delivering 5.5 kW (7.5 HP) of power, this drive is designed for high-torque tasks such as heavy-duty conveyors, precision positioning systems, and industrial mixers. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-302P5K5T5E20H2XGC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands out for its extreme reliability, featuring factory-coated PCBs for protection against harsh environments and an integrated Graphical Local Control Panel (LCP) for intuitive onsite monitoring and programming. Its sophisticated control logic allows for seamless integration into complex automated systems, providing the high-speed response and motor shaft performance required in modern smart factories.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe VLT® AutomationDrive FC 302 platform is a modular, future-ready solution built for the most demanding technical requirements. This specific configuration operates on a wide three-phase mains voltage of 380 - 500 V and includes an H2 RFI filter for superior electromagnetic compatibility (EMC). A critical feature of this model is the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"C\" Option (Coated PCB)\u003c\/strong\u003e, which provides an extra layer of protection against moisture, dust, and corrosive chemicals, significantly extending the drive's service life in industrial settings. The inclusion of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGraphical LCP (G)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for full-text parameter access and real-time performance graphing, facilitating rapid troubleshooting and commissioning without the need for an external PC.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-302P5K5T5E20H2XGC (131B0151)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.5 kW \/ 7.5 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase 380 - 500 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThree Phase (T)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRFI Filter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH2 (RFI Filter)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePCB Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoated (C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Panel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGraphical LCP Included (G)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrake Chopper\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone (X)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.05 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Coated PCB (C option) benefit my industrial application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn environments such as wastewater treatment, chemical processing, or textiles, airborne contaminants can cause conductive tracks on circuit boards to short-circuit. The coating on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131B0151\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecreates a chemical-resistant barrier, ensuring the drive remains operational where standard drives might fail due to \"pollution degree 3\" conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the Graphical LCP be used to copy parameters to other drives?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The Graphical LCP (G) features a built-in memory function. You can save a complete parameter set from one 5.5 kW FC-302 and \"upload\" it to another drive of the same series, significantly reducing commissioning time for multi-drive systems or during maintenance replacements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this drive suitable for high-inertia loads that require fast braking?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific model (Code X) does not include a built-in brake chopper. For applications requiring rapid deceleration of heavy loads, you would either need a variant with an integrated brake chopper or implement an external regenerative unit to manage excess energy and prevent DC-link overvoltage trips.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Compliance \u0026amp; Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure the H2 RFI filter functions correctly, use a shielded motor cable. The shield must be terminated at both ends—using a 360-degree HF clamp at the drive's metal decoupling plate and a proper gland at the motor terminal box. This minimizes high-frequency noise that could interfere with sensitive control signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC 302 relies on its internal fans for cooling. For the IP20 chassis, ensure a minimum of 100 mm clearance above and below the unit for vertical airflow. Monitor the cabinet temperature to ensure it stays within the -10 to 45 deg C range to maintain the full 5.5 kW output without thermal derating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilize the digital and analog inputs to maximize the drive's built-in Smart Logic Controller. For long cable runs for the analog reference (0-10V or 4-20mA), use twisted-pair shielded cables and keep them at least 200 mm away from power cables to avoid signal corruption that could lead to speed instability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419575147,"sku":"131B0151","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131b0151-z51wipke5sj.png?v=1776137000","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-vlt-automationdrive-fc-302p5k5t5e20h2xgc-5-5kw","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}