{"product_id":"danfoss-vlt-hvac-basic-drive-fc-101p7k5t4e20h4","title":"Variateur HVAC basique Danfoss VLT FC-101P7K5T4E20H4","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131L9868 (131L9868)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency VLT® HVAC Basic Drive FC-101, specifically engineered by Danfoss to meet the rigorous demands of heating, ventilation, and air conditioning systems. Delivering a robust 7.5 kW (10 HP) of power, this frequency converter is the ideal solution for optimizing fan and pump performance in commercial and industrial building automation. By utilizing advanced variable speed control, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-101P7K5T4E20H4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reduces energy consumption and mechanical wear on motor-driven systems. Its compact IP20 enclosure is designed for cabinet mounting, providing a cost-effective, \"fit-and-forget\" solution that enhances system reliability and reduces the total cost of ownership for HVAC infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe FC-101 series is built on a streamlined hardware platform that prioritizes ease of installation and high energy efficiency. This unit operates on a three-phase 380 - 480 VAC mains supply and includes a built-in H4 RFI filter (Class A1\/C2), ensuring compliance with electromagnetic compatibility standards in most industrial and commercial environments. The drive features an integrated HVAC-specific software suite, including a built-in PID controller for pressure and flow regulation, as well as a specialized \"Fire Mode\" for safety-critical smoke extraction fans. The 4.9 kg lightweight chassis is optimized for DIN rail or backplate mounting, and its modular design allows for rapid parameter setup using the local control panel or PC-based software.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-101P7K5T4E20H4 (131L9868)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 kW \/ 10 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase 380 - 480 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRFI Filter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH4 (Class A1\/C2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThree Phase (T)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 98%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 40 deg C (Full load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.9 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this drive support communication protocols common in HVAC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The FC-101 series comes standard with built-in FC Protocol, Modbus RTU, and BACnet (MS\/TP). This allows the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e131L9868\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto integrate seamlessly into Building Management Systems (BMS) for remote monitoring and centralized control of 7.5 kW motor loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the H4 RFI filter in a commercial building?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe H4 (Class A1\/C2) filter minimizes electromagnetic interference generated by the drive. This is critical in commercial settings to prevent the drive from disrupting sensitive electronics, communication lines, or office equipment sharing the same power grid.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 131L9868 be used with permanent magnet (PM) motors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe VLT® HVAC Basic Drive is primarily optimized for standard induction motors. While it provides excellent control for asynchronous motors, users requiring high-performance PM motor control should verify compatibility with the specific firmware version (SXXX) or consider the FC-102 series for advanced motor motor technology support.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAirflow Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC-101 relies on vertical convection for cooling. Ensure a minimum of 100 mm clearance above and below the drive. Since this model is IP20, it must be installed in a clean, dry cabinet where the ambient temperature does not exceed 40 deg C to maintain the 7.5 kW power rating without derating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFire Mode Implementation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilizing the Fire Mode for life-safety applications, ensure the control logic is wired to a dedicated digital input. Note that when Fire Mode is active, the drive will ignore most internal protective trips to keep the fan running as long as possible; therefore, periodic testing of this loop is essential.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain RFI Class A1 compliance, use shielded motor cables. The shield should be terminated with a 360-degree HF clamp at the drive's metal decoupling plate. Avoid \"pigtail\" grounding of the shield, as this creates high-frequency impedance and reduces the effectiveness of the H4 filter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102419673451,"sku":"131L9868","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/131l9868-0fnkjojdnbh.png?v=1776137020","url":"https:\/\/www.plcprotech.com\/fr\/products\/danfoss-vlt-hvac-basic-drive-fc-101p7k5t4e20h4","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}