{"product_id":"delta-ahacabe0-5a-ah500-series-backplane-extension-cable","title":"DELTA AHACABE0-5A Série AH500 Câble d'extension de backplane","description":"\u003ch3\u003eInterconnection Overview \u0026amp; System Reliability\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAHACABE0-5A (AHACABE05A)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, double-shielded backplane extension cable engineered specifically for the Delta AH500 programmable logic controller platform. Spanning a length of 50.0 meters, this heavy-duty communication link permits the physical separation of main CPU racks from secondary expansion racks across large industrial installations, such as automated material handling facilities, continuous chemical processing plants, and water treatment facilities.\u003c\/p\u003e\n\u003cp\u003eBy facilitating high-bandwidth bus extensions directly over extended distances, the cable ensures real-time deterministic synchronization between local processing units and remote I\/O subsystems. This architectural flexibility eliminates the latency penalties associated with standard fieldbus networks, maintaining optimal machine throughput and minimizing system downtime during high-speed sequential control execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Interface \u0026amp; Rack Compatibility\u003c\/h3\u003e\n\u003cp\u003eConstructed with heavy-duty connectors (HDC) to withstand the mechanical and electrical rigors of industrial environments, the cable provides reliable connection stability under sustained vibration. The internal wiring features a low-attenuation, twisted-pair copper design surrounded by an integrated foil and braided shield to block high-frequency electromagnetic interference (EMI) over the entire 50.0-meter span.\u003c\/p\u003e\n\u003cp\u003eThis specific expansion link is engineered for seamless plug-and-play integration with Delta's modular backplanes, allowing technical personnel to expand system capacity without modifying core control software architecture or adding specialized communication modules.\u003c\/p\u003e\n\u003ch3\u003eComponent Interconnect Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAHACABE0-5A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDELTA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTaiwan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHeavy-Duty Backplane Extension Cable (HDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50.0 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Main Backplanes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAHBP04M1-5A, AHBP06M1-5A, AHBP08M1-5A, AHBP12M1-5A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Expansion Backplanes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAHBP06E1-5A, AHBP08E1-5A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShielding Matrix\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-core twisted pair with overall braided copper shield\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Integrity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial-grade locking HDC mechanisms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBending Radius (Minimum)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFixed installation: 8x Outer Diameter; Dynamic: 12x Outer Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOuter Jacket Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOil-resistant, flame-retardant Polyurethane (PUR)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.62 kg (Shipping Weight: 1.0 kg due to heavy protective spooling)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +75 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Queries \u0026amp; Field Diagnostics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes a 50-meter cable length introduce data propagation delays into the I\/O bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The AH500 system architecture accounts for propagation delays across the full length of the AHACABE0-5A connection. The internal hardware timing and hardware-level handshake protocols automatically compensate for the line impedance over 50.0 meters, ensuring consistent microsecond-level I\/O response times across all expansion racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat symptoms occur if the extension cable is damaged or improperly seated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn unseated or compromised extension link typically triggers a hardware fault LED on the primary CPU module, signaling a loss of communication with the expansion rack. The controller registers an I\/O disconnection error, and the safety routines immediately force the outputs on the affected remote backplane into their pre-configured fail-safe states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be modified or spliced in the field to match shorter run lengths?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSplicing or cutting this high-speed bus extension cable is strictly prohibited. The factory-molded HDC connectors and specific internal impedance tuning are calibrated precisely for the 50.0-meter length. Field alterations disrupt the shielding integrity and cause signal reflections, resulting in data corruption and unpredictable system resets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eField Commissioning \u0026amp; Safety Protocols\u003c\/h3\u003e\n\u003ch3\u003eRouting and EMI Isolation\u003c\/h3\u003e\n\u003cp\u003eDo not lay the 50.0-meter extension cable inside cable trays containing high-power AC motor leads, variable frequency drive (VFD) outputs, or high-voltage distribution lines. Maintain a minimum separation distance of 300 mm from all power cabling. If the cable must cross high-voltage paths, it must cross strictly at a 90-degree angle within a dedicated, grounded steel conduit to eliminate capacitive noise coupling.\u003c\/p\u003e\n\u003ch3\u003eCable Pulling Tension and Bend Limits\u003c\/h3\u003e\n\u003cp\u003eDuring installation through conduits or cable tracks, the pulling tension must not exceed 100 N to prevent internal conductor stretching or shield degradation. Adhere strictly to the minimum bending radius specification. Sharp bends or kinks alter the characteristic impedance of the twisted pairs, which can generate communication faults during periods of peak backplane data traffic.\u003c\/p\u003e\n\u003ch3\u003eConnector Strain Relief and Grounding\u003c\/h3\u003e\n\u003cp\u003eWhen plugging the cable into the AHBP series main or expansion backplanes, verify that the locking tabs are fully engaged and clicked into position. Secure the cable jacket to the cabinet structural rail using an integrated strain-relief clamp within 100 mm of the connector body. This prevents the physical mass of the 50.0-meter vertical cable run from applying continuous mechanical stress to the delicate backplane socket pins.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102411645291,"sku":"AHACABE0-5A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/AHACABE0-5A-z3e03o200b5.png?v=1776137210","url":"https:\/\/www.plcprotech.com\/fr\/products\/delta-ahacabe0-5a-ah500-series-backplane-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}