{"product_id":"delta-ahcpu510-en-ah-series-cpu-module","title":"DELTA AHCPU510-EN Module CPU série AH","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAHCPU510-EN (AHCPU510EN)\u003c\/strong\u003e is a high-performance central processing unit (CPU) module from the Delta AH series, designed to serve as the brain of large-scale, mission-critical industrial automation systems. With a program capacity of 64K steps (256 KB) and an exceptionally fast execution speed (0.1 microseconds for LD instructions), this module is engineered for high-speed data processing and complex logic control in sectors such as automotive manufacturing, automated assembly lines, and water treatment plants. The AHCPU510-EN integrates seamlessly into the AH series backplane architecture, supporting up to 1,280 local I\/O points to minimize system latency and maximize total factory output.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture of the AHCPU510-EN is built for maximum connectivity and diagnostic transparency. It features a robust suite of communication interfaces, including a multi-mode RS-232\/422\/485 port, a high-speed 100 Mbps Ethernet port, and a dedicated mini-USB programming interface. The module supports a variety of industrial programming languages—LD, SFC, FBD, IL, and ST—adhering to IEC 61131-3 standards. Notably, the AHCPU510-EN utilizes flash memory for program storage, eliminating the need for a battery for data retention, while its integrated SD card slot allows for easy data logging and program backups.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAHCPU510-EN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDELTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eTaiwan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Capacity\u003c\/td\u003e\n\u003ctd\u003e64 K steps (256 KB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Speed\u003c\/td\u003e\n\u003ctd\u003e0.1 microseconds (LD instruction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal I\/O\u003c\/td\u003e\n\u003ctd\u003e1280 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet (100 Mbps), RS-232\/422\/485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Register (D\/L\/B)\u003c\/td\u003e\n\u003ctd\u003e32 K \/ 32 K \/ 1024 K words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming\u003c\/td\u003e\n\u003ctd\u003eLD, SFC, FBD, IL, ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the AHCPU510-EN require a battery to retain the program?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this module utilizes flash memory for program storage, which ensures the user program remains intact even without power. A real-time clock (RTC) is included, which maintains time for up to 30 days after power-off using built-in capacitors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the PLC Link function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePLC Link allows for automatic data exchange between multiple Delta PLCs over the communication network without requiring explicit programming for each data packet, drastically simplifying the synchronization of multi-controller systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I monitor the PLC remotely?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the built-in Ethernet port supports WEB server functionality and E-mail alerts, allowing maintenance staff to monitor system status or receive fault notifications remotely via a standard web browser or e-mail client.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Engineering Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment and Thermal Management:\u003c\/strong\u003e While the AHCPU510-EN has a very low power consumption of 2 W, it is crucial to ensure it is installed in a clean, dust-free enclosure to prevent conductive particles from settling on the exposed communication ports or backplane connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Security:\u003c\/strong\u003e Given the unit's built-in Ethernet functionality (WEB\/E-mail), always utilize the IP Filter function to restrict access to trusted internal machine network devices only. This is a critical security step for any internet-connected industrial automation controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupt Optimization:\u003c\/strong\u003e The controller supports 256 interrupts. For high-speed applications (e.g., high-speed counting or critical external events), map these interrupts carefully to avoid \"jitter\" in the main scan cycle, which can occur if too many tasks are triggered simultaneously.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102230471019,"sku":"AHCPU510-EN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/AHCPU510-EN-w0wl1zwy4jd.png?v=1776137223","url":"https:\/\/www.plcprotech.com\/fr\/products\/delta-ahcpu510-en-ah-series-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}