{"product_id":"delta-vfd040cb43a-20-c200-series-economy-vector-control-drive","title":"Variateur à commande vectorielle économique série Delta VFD040CB43A-20 C200","description":"\u003ch3\u003eIndustrial System Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDelta VFD040CB43A-20 (VFD040CB43A-20)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an intelligent, cost-effective variable frequency drive engineered within the Delta C200 smart vector control family. Deployed globally across decentralized commercial and industrial automation processes—such as heavy-duty packaging machinery, high-speed textile winders, industrial woodworking saws, and multi-zone conveyor networks—this drive regulates three-phase induction motors. By packing high-performance vector algorithms into a compact, wall-mounted frame, the drive ensures stable speed regulation, lowers operating overhead, and protects delicate transmission components from sudden starting torque shocks.\u003c\/p\u003e\n\u003ch3\u003ePower Architecture and Vector Control Dynamics\u003c\/h3\u003e\n\u003cp\u003eThis wall-mount frequency converter operates on a 460 V three-phase input supply, drawing a nominal input current of 15.5 A to deliver an applicable motor capacity of 4.0 kW (5.5 HP). It features four software-selectable control methods: standard V\/F control, Sensorless Vector Control (SVC), V\/F control with encoder feedback (VF+PG), and Field Oriented Control with encoder feedback (FOC+PG). Designed with dual-rating operational thresholds, the drive achieves a maximum output frequency of up to 600.00 Hz under Normal Duty parameters, or up to 300.00 Hz under Heavy Duty parameters, backed by a maximum torque limit threshold of 200% torque current.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Duty (ND) Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eHeavy Duty (HD) Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVFD040CB43A-20\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVFD040CB43A-20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand \/ Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDelta Electronics \/ Smart Economy C200 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDelta Electronics \/ Smart Economy C200 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplicable Motor Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 kW (5.5 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 kW (5.5 HP) Optimized for Constant Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Frequency Spectrum\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.00 to 600.00 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.00 to 300.00 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Control Methods\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eV\/F, SVC, VF+PG, FOC+PG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eV\/F, SVC, VF+PG, FOC+PG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTorque Overload Ceiling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e--\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 200% torque current capability\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Supply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e460 V Three-Phase AC Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e460 V Three-Phase AC Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMechanical Installation Mode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eA Type (Wall mount format)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eA Type (Wall mount format)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIngress Safety Shield\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ UL Open Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ UL Open Type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Device Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Gross Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg (Enclosed in shock-resistant packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg (Enclosed in shock-resistant packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Diagnostics and FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do you determine whether to configure the C200 drive for SVC versus FOC+PG mode?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSensorless Vector Control (SVC) should be selected for standard high-performance applications where an encoder cannot be physically mounted to the motor shaft, as it calculates rotor position mathematically using internal electrical models. Field Oriented Control with PG card encoder feedback (FOC+PG) must be implemented for advanced processes requiring precise speed regulation near zero RPM, absolute position holding, or high dynamic torque responsiveness.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat action must be taken if the drive trips on an overcurrent fault (OC) during sudden starting phases?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn instantaneous OC trip during initialization indicates that the output current exceeded the safety threshold. First, verify that the active motor nameplate metrics match the data inside the drive's parameter bank. Next, check the mechanical line for binding or jams, and evaluate the torque limit parameter; the VFD040CB43A-20 can handle up to 200% torque current, so increasing the acceleration time or adjusting the V\/F curve offset can often stabilize high-inertia starting cycles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this drive require an external cooling fan unit for enclosed control panels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive features an integrated heatsink structure sized to dissipate the heat generated by the 4.0 kW power stage. However, because it carries an IP20 open-type rating, it must be mounted inside a ventilated electrical enclosure. Ensure the air flowing through the cabinet is free of conductive metallic dust and moisture mist to protect the exposed power terminals.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Commissioning and Wiring Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMain Potential Rail Connections:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLand the incoming 460 V three-phase utility power lines exclusively onto terminals R\/L1, S\/L2, and T\/L3. Connect the output cables going directly to the induction motor terminals onto U\/T1, V\/T2, and W\/T3. Never land raw utility power onto terminals U, V, or W, as applying line voltage directly to the inverter switching block will instantly destroy the internal solid-state output transistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEncoder (PG Card) Separation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilizing the VF+PG or FOC+PG control modes, route the encoder feedback signal cable through separate wire pathways away from the high-voltage motor lines. The encoder cable must utilize shielded twisted pairs with the overall braid grounded at a single point near the drive's chassis ground. This separation prevents PWM switching transients from coupling into the feedback register and causing speed tracking errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Mounting Layout and Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInstall the wall-mount frame vertically onto a flat, unpainted metallic sub-panel to maximize conductive grounding properties. Maintain an open perimeter boundary of at least 50 mm on both sides and a minimum vertical clearance of 120 mm above and below the drive housing. Inspect the unit regularly to ensure the cooling fins remain clear of airborne fibers or grease, which can degrade thermal efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102409908587,"sku":"VFD040CB43A-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vfd040cb43a-20-sbgbmmkgils.png?v=1776138045","url":"https:\/\/www.plcprotech.com\/fr\/products\/delta-vfd040cb43a-20-c200-series-economy-vector-control-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}