{"product_id":"delta-vfd220e43a-ac-motor-drive-e-series","title":"DELTA VFD220E43A Variateur moteur AC série E","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVFD220E43A (VFD220E43A)\u003c\/strong\u003e is a heavy-duty AC motor drive from the Delta E series, specifically configured for industrial applications requiring 22 kW (30 HP) of output power. Operating on a three-phase 460 V supply, this drive is a versatile solution for systems where robust performance and compact integration are critical. It is commonly deployed in HVAC centrifugal fans, water treatment pumps, and industrial material handling systems. By utilizing Delta’s proven E-series technology, the VFD220E43A provides reliable speed control that helps minimize mechanical shock during startup and reduces overall energy expenditure in long-cycle industrial processes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe E series is recognized for its modular \"all-in-one\" design, which integrates essential control functions into a single, compact chassis. The VFD220E43A is built to handle high-demand loads while maintaining operational stability through a sophisticated fan-cooled thermal management system. The drive features programmable acceleration and deceleration ramps to protect mechanical gearboxes and couplings from torque spikes. With built-in standard I\/O points and support for common communication interfaces, it can be quickly commissioned into existing PLC-based control architectures, reducing both installation time and complexity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVFD220E43A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDELTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eTaiwan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.47 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e22 kW (30 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e460 VAC (3-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eE Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersion\u003c\/td\u003e\n\u003ctd\u003eStandard (A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eFan Cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat makes the E series different from the B or C2000 series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe E series is categorized as a compact, multi-functional, and low-noise drive. It is designed for general-purpose applications that require a balance between features and cost-effectiveness, whereas the C2000 series is built for higher-end, complex field-oriented control (FOC) tasks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this drive require external cooling in a control cabinet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe VFD220E43A features an integrated internal fan. However, if installed within a closed cabinet, the cabinet must have an active exhaust system or louvers to ensure the internal ambient temperature does not exceed 50 deg C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the VFD220E43A capable of handling dynamic braking?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the E series supports external braking resistors for applications where high-inertia loads require rapid deceleration, such as centrifuges or indexing conveyor systems. Ensure the resistor wattage is sized correctly for the specific duty cycle.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Best Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation Clearance:\u003c\/strong\u003e To maximize the lifespan of the internal cooling fan and capacitors, maintain a minimum of 150 mm of vertical clearance above and below the drive. Avoid mounting the drive in areas where it is exposed to direct sunlight or high-moisture mist.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Always use 4-core shielded cables for the motor connection. The shield must be bonded to the motor chassis and the drive's PE terminal to prevent high-frequency noise from interfering with nearby analog sensors or communication lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeriodic Maintenance:\u003c\/strong\u003e As a fan-cooled unit, the VFD220E43A is susceptible to dust accumulation. Perform a quarterly inspection of the air intake vents; use dry, low-pressure compressed air to clear any debris to ensure the internal heat sink maintains optimal thermal exchange.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102240956779,"sku":"VFD220E43A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vfd220e43a-2b41y0alv5l.png?v=1776138082","url":"https:\/\/www.plcprotech.com\/fr\/products\/delta-vfd220e43a-ac-motor-drive-e-series","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}