{"product_id":"delta-vfd370cp23a-00-intelligent-sensorless-vector-control-drive","title":"DELTA VFD370CP23A-00 Variateur à commande vectorielle sans capteur intelligent","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVFD370CP23A-00 (VFD370CP23A00)\u003c\/strong\u003e is a heavy-duty, intelligent AC motor drive from Delta’s CP2000 series, specifically engineered for high-power applications requiring 37 kW (50 HP) of output. Designed for 230 V three-phase power grids, this drive utilizes sophisticated sensorless vector control (SVC) to manage large-scale industrial loads with exceptional precision. It is widely utilized in municipal water treatment facilities, HVAC systems, and large-scale industrial fluid management, where energy optimization and continuous torque stability are essential for minimizing downtime and maximizing long-term mechanical efficiency.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe CP series is characterized by its high-intelligence control platform, capable of delivering stable performance across a wide frequency range (up to 600 Hz). The VFD370CP23A-00 is optimized for variable-torque loads, allowing it to dynamically adjust power consumption based on real-time process demand. The hardware features an IP00\/UL Open Type protection rating, intended for integration into dedicated control cabinets where external environmental factors are managed. Its high current rating of 146 A provides the overhead necessary for demanding startup sequences and rapid load stabilization in high-inertia environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVFD370CP23A-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDelta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eTaiwan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e37.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e37 kW (50 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e146 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e58 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e230 VAC (3-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Frequency\u003c\/td\u003e\n\u003ctd\u003e600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP00 (UL Open Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 'CP' series designation imply compared to the C or E series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CP series is specifically optimized for fluid control applications (pumps, fans, blowers). It includes specialized internal logic for PID control, fire mode, and automatic bypass control, which are not standard in general-purpose C or E series drives.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSince the drive is rated IP00, what cabinet requirements must I meet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBeing an IP00\/UL Open Type device, the drive offers no ingress protection against dust or moisture. It MUST be mounted inside a NEMA-rated or IP-rated electrical enclosure. Furthermore, since the unit relies on high-velocity airflow, the enclosure must be sized for adequate CFM (cubic feet per minute) to prevent thermal shutdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 600 Hz maximum frequency output benefit my application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile most pumps and fans operate at standard line frequencies, the 600 Hz output allows for the use of high-speed spindles or specialized high-RPM compressors that require higher excitation frequencies to reach their rated operational speeds.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Best Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Given the 146 A output, heat dissipation is the primary concern for the VFD370CP23A-00. Install the drive in a vertical orientation. Ensure that the cabinet's intake filters are cleaned monthly to prevent dust buildup on the internal heat sink, which is critical for a 37 kW drive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e To ensure high-frequency stability, the drive chassis must be connected to a central grounding busbar using a low-impedance copper cable. Given the high power throughput, any floating ground will lead to significant electrical noise that may corrupt sensor signals (e.g., pressure transducers or flow meters) connected to the PID loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Selection:\u003c\/strong\u003e For a 37 kW application, use high-temperature-rated power cables (e.g., THHN\/THWN) for the output motor connection. Ensure that all power leads are routed through dedicated shielded conduits and kept at least 300 mm away from low-voltage communication lines to mitigate radiated EMI.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102230929771,"sku":"VFD370CP23A-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vfd370cp23a-00-rqw4ammfnyk.png?v=1776138096","url":"https:\/\/www.plcprotech.com\/fr\/products\/delta-vfd370cp23a-00-intelligent-sensorless-vector-control-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}