{"product_id":"delta-vfd750c43a-00-c2000-series-high-power-variable-frequency-drive","title":"DELTA VFD750C43A-00 Variateur de fréquence haute puissance série C2000","description":"\u003ch3\u003eHigh-Performance System Drive Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVFD750C43A-00 (VFD750C43A-00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty, high-power variable frequency drive engineered by Delta within the flagship C2000 Series platform. Delivering a robust 75 kW (100 HP) of output capacity and a rated continuous output current of 150 Amps, this field-oriented control drive is optimized for high-inertia and high-torque industrial automation processes. In critical heavy industries such as oil refining, deep-well mining operations, metal processing mills, and large-scale water distribution facilities, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVFD750C43A-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotects mechanical drivetrains and curtails unexpected production downtime through real-time torque regulation, built-in PLC capabilities, and exceptional overload capacity. Its high-power Frame D design provides the dependable thermal and electrical performance necessary to keep continuous plant machinery running smoothly under variable load demands.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eDelta utilizes an organized alphanumeric code to define the structural and electrical options of the C2000 platform:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVFD\u003c\/strong\u003e: Variable Frequency Drive (Product Classification)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e750\u003c\/strong\u003e: 75 kW (100 HP) applicable motor power rating (Frame D chassis size)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eC\u003c\/strong\u003e: C2000 Series designated for field-oriented vector control and heavy-duty performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e43\u003c\/strong\u003e: 460 V AC, 3-phase incoming line voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Wall-mountable mechanical structure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: IP00 protection rating level (Open Type chassis requiring an external electrical enclosure)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Technical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following performance parameter matrix details the mechanical, electrical, and environmental limits verified for heavy-duty system deployment:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVFD750C43A-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDELTA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTaiwan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Philosophy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eField Oriented Control (FOC), SVC, V\/f, PM Sensorless\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 Amps (Continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMotor Power Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 kW \/ 100 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380 V AC to 480 V AC (3-phase, 50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Frequency Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 to 600 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverload Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150% of rated current for 60 seconds (Heavy Duty cycle)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP00 \/ Open Type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 40 deg C (without derating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Structural Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Frame D engineering chassis specification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.50 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Knowledge Base \u0026amp; Common Inquiries\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary safety considerations when mounting an IP00 rated drive chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn IP00 rating means the drive features an open chassis design with exposed electrical busbars and power terminals. It has zero native protection against dust, moisture, or accidental human contact. It must be installed inside a dedicated, key-locked industrial control cabinet that meets the appropriate IP\/NEMA environmental protection standards required for the factory floor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the integrated field-oriented control (FOC) enhance motor execution?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FOC vector algorithm mathematically decouples the motor's stator current into independent torque-producing and flux-producing components. By measuring real-time phase currents, it achieves exceptional dynamic response, precise speed regulation down to zero speed, and maximum starting torque for heavy loads like loaded conveyor systems or high-pressure positive displacement pumps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this C2000 drive run modern Permanent Magnet (PM) synchronous motors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the C2000 architecture is a hybrid drive platform. It provides native firmware algorithms to drive traditional squirrel-cage AC induction motors as well as high-efficiency permanent magnet synchronous motors (IPMSM \/ SPMSM) in both open-loop sensorless modes and closed-loop encoder feedback configurations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Commissioning \u0026amp; Safety Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Thermal Design and Clearances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBecause this 75 kW drive generates significant internal heat dissipation under 150 Amp continuous loads, mount the Frame D chassis vertically inside the control cabinet. Maintain an unobstructed clearance margin of at least 75 mm on both sides and 150 mm above and below the cooling fan assemblies. Ensure the cabinet's forced-air ventilation or air conditioning system maintains an internal temperature below 40 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Conductor and Terminal Torque Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure all heavy-gauge input cables (R\/L1, S\/L2, T\/L3), output motor runs (U\/T1, V\/T2, W\/T3), and external DC braking resistors are securely clamped. Fasten all terminal hardware to the exact high-torque level specified in the Frame D manual. Loose connections yield localized thermal stress, serious arcing risks, and major phase-voltage unbalances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Frequency Electromagnetic Interference Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRun a continuous, shielded VFD-rated cable between the drive and the motor. Ground the braided copper shield tightly at both the drive enclosure ground bar and the motor junction box frame. This low-impedance pathway safely redirects high-frequency PWM switching noise away from nearby 24 VDC control wiring and sensitive instrumentation networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102408171883,"sku":"VFD750C43A-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vfd750c43a-00-evqsqfxeqyv.png?v=1776138109","url":"https:\/\/www.plcprotech.com\/fr\/products\/delta-vfd750c43a-00-c2000-series-high-power-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}