{"product_id":"delta-vfd9a0mh43ansaa-mh300-series-variable-frequency-drive","title":"Variateur de fréquence série Delta VFD9A0MH43ANSAA MH300","description":"\u003ch3\u003eProcess Automation Drive Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDelta VFD9A0MH43ANSAA (VFD9A0MH43ANSAA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, compact sensorless vector control AC motor drive engineered within the versatile Delta MH300 frequency converter family. Deployed globally across heavy-duty processing industries such as automated tool changers, ceramic manufacturing extruders, continuous textile tensioning webs, and centrifugal pump stations, this variable speed drive regulates asynchronous and permanent magnet motors. By implementing advanced motor parameter auto-tuning algorithms alongside dual-rating operational profiles, the frequency converter optimizes mechanical torque output, stabilizes speed variations under shifting mechanical loads, and protects downstream machinery from high-stress starting currents.\u003c\/p\u003e\n\u003ch3\u003ePower Architecture and Thermal Ratings\u003c\/h3\u003e\n\u003cp\u003eThis Frame C frequency converter features an adjustable power stage rated for three-phase AC inputs between 380 V and 480 V (-15% \/ +10%). It operates reliably across an absolute input voltage range of 323 to 528 VAC at line frequencies from 47 to 63 Hz. Built using an integrated dual-load rating model, the drive provides a Heavy Duty configuration delivering 9.0 A continuous output (3.7 kW \/ 5 HP motor capacity) or a Normal Duty configuration supporting up to 10.5 A continuous output (for variable torque fan and pump loads). The chassis incorporates an IP20 ingress protection rating and utilizes a highly efficient natural cooling framework that eliminates mechanical fan vibration and extends operating life in dust-controlled enclosures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eHeavy Duty (HD) Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Duty (ND) Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVFD9A0MH43ANSAA (Replaces VFD5A7MH43ANSAA variants)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand \/ Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDelta Electronics \/ High-Performance MH300 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Physical Frame\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFrame C Design Layout\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplicable Motor Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.7 kW (5 HP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.7 kW (5 HP) Optimized for Variable Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Output Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.9 kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Incoming Line Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.9 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.6 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCarrier Frequency Spectrum\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 to 15 kHz (Factory default value: 4 kHz)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 to 15 kHz (Factory default value: 4 kHz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLine Voltage \/ Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-phase 380V to 480VAC (-15% \/ +10%), 50\/60 Hz mains\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAbsolute Operational Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e323 to 528 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIngress Safety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 Open Type Architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural cooling (Fanless high-mass heatsink design)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEMC Interference Filtering\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptional hardware module attachment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.85 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Gross Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg (Enclosed in heavy-duty industrial carton)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Diagnostics and FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do you determine whether to configure the frequency converter for Heavy Duty or Normal Duty?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis choice is managed through the drive's internal control parameters in group 00. For constant-torque applications requiring high starting torque or frequent overload surges (such as conveyors, mixers, or mechanical cutting axes), configure the module for Heavy Duty to utilize the 9.0 A baseline with higher overload headroom. For variable-torque configurations where torque increases with speed (such as centrifugal fans or cooling pumps), select Normal Duty to utilize the higher 10.5 A output continuous rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary troubleshooting steps if an overcurrent fault (OC) occurs immediately upon motor acceleration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst, check that the motor nameplate metrics (KW, Voltage, Full Load Amps) accurately match the parameters programmed into the drive's motor parameter group. Next, decouple the motor shaft from the mechanical load and run a rotational or static auto-tune to calibrate the stator resistance values. If the fault persists when decoupled, inspect the motor lines for insulation breakdown or phase-to-ground faults using a megohmmeter, and ensure the acceleration time parameter is not set too low for the load inertia.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does this specific 3.7 kW drive utilize natural cooling instead of an integrated fan assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe VFD9A0MH43ANSAA features an oversized, high-surface-area aluminum heatsink configuration engineered to transfer thermal energy away from the internal IGBT switches without relying on active forced air. This fanless design improves long-term reliability in environments containing airborne fibers, fine non-conductive dust, or vaporized oils, which frequently clog or seize standard internal cooling fan bearings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Commissioning and Wiring Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMain Power Terminal Block Layout:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLand incoming three-phase AC supply lines strictly on terminals R\/L1, S\/L2, and T\/L3. Connect the output motor leads to terminals U\/T1, V\/T2, and W\/T3. Never connect raw incoming line voltage to the output terminals U, V, or W, as applying mains potential directly to the internal inverter block will cause immediate, irreversible damage to the solid-state output transistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCarrier Frequency and Noise Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf the application requires long motor cable runs exceeding 20 meters, or if audible motor hum is a problem, the carrier frequency can be adjusted between 2 and 15 kHz. Note that increasing the carrier frequency above the factory default of 4 kHz increases internal thermal generation and capacitive leakage currents. If you increase the carrier frequency, derate the continuous output current slightly or install an output line reactor to protect the motor winding insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Mounting Clearances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMount the Frame C drive vertically on a flat, unpainted metallic sub-panel to maximize conductive thermal dissipation. Because this unit relies completely on natural convection, maintain an open clearance boundary of at least 50 mm on both sides and a minimum of 120 mm above and below the heatsink chassis. Ensure that ambient air temperatures inside the cabinet do not exceed the standard limits, and vent any heat generated by adjacent power components away from the base of this drive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102410760555,"sku":"VFD9A0MH43ANSAA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vfd9a0mh43ansaa-ap44hao3arv.png?v=1776138115","url":"https:\/\/www.plcprotech.com\/fr\/products\/delta-vfd9a0mh43ansaa-mh300-series-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}