{"product_id":"e70acmse0204sa1etr-lenze-i700-double-inverter-module","title":"Module double variateur Lenze i700 E70ACMSE0204SA1ETR","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE70ACMSE0204SA1ETR (E70ACMSE0204SA1ETR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density \"Double Inverter\" module from the Lenze i700 series, designed specifically for multi-axis systems powered by a common DC bus. This state-of-the-art unit integrates two independent drive power stages into a single compact housing, each capable of a 5 A rated current. Engineered for DC-coupled drive architectures operating between 565 and 675 VDC, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE70ACMSE0204SA1ETR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reduces the installation footprint and wiring complexity compared to traditional single-axis drives. It comes standard with dual resolver feedback interfaces, making it an ideal solution for synchronized motion in robotic handling, multi-stage packaging lines, and textile processing. As an active part of the Lenze 9400-series ecosystem, it combines German engineering precision with the \"Safe Torque Off (STO)\" safety function to ensure maximum operational security and system uptime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE70ACMSE0204SA1ETR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for centralized control via EtherCAT, providing deterministic synchronization between the two internal axes. The \"Double Inverter\" design allows both axes to share a single DC bus connection, facilitating energy exchange between motoring and regenerating axes. The unit features integrated resolver evaluation for high-accuracy position feedback and is built with a robust IP20 chassis. The \"SA\" designation typically refers to the integrated Safety Address or specific safety configuration, while the \"ETR\" suffix denotes the EtherCAT communication protocol, which is native to the i700 series for seamless integration into high-speed automation networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE70ACMSE0204SA1ETR\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLenze\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ei700 (9400-series ecosystem)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInverter Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDouble Inverter (Dual Axis)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x 5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC Bus Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e565 to 675 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFeedback Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x Resolver\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEtherCAT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafe Torque Off (STO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35.0 x 26.1 x 10.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.18 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary advantages of the i700 Double Inverter over single-axis drives?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe double inverter configuration reduces the number of DC bus supply components and occupies up to 50% less space on the DIN rail. It also simplifies the thermal management of the cabinet by consolidating heat dissipation into fewer units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require a separate power supply for the control electronics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, while the power stage runs off the 565\/675 VDC bus, the control electronics and safety circuits typically require a separate 24 VDC supply to maintain communication and safety monitoring even when the high-voltage DC bus is discharged.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the STO safety function implemented on a double-axis unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe STO (Safe Torque Off) mechanism on the E70ACMSE0204SA1ETR is designed to safely prevent the drive from restarting by cutting power to the motor's rotating field. Depending on the configuration, STO can often be triggered independently for each axis or globally for the entire module.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Bus Connection and Fusing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the DC bus connections (typically labeled +UG and -UG) are made with short, low-inductance wires. Given the 565\/675 V operating range, high-speed semiconductor fuses must be used on the DC supply side to protect the inverter's power stage against bridge-layer faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolver Feedback Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain signal integrity for the 2 x 5 A outputs, resolver cables must be high-quality, double-shielded twisted pairs. Route these cables away from the DC bus and motor power lines to prevent electromagnetic interference from causing position \"jitter\" or feedback faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling and Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe i700 series is designed for vertical mounting. Ensure the top and bottom ventilation slots are not obstructed. Since this module houses two inverters, monitor the total heat loss (approx. 100-150W at full load) and ensure the cabinet’s internal circulation is sufficient to keep the intake air below 45 Celsius.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105064575339,"sku":"E70ACMSE0204SA1ETR","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e70acmse0204sa1etr-rzf3mmhy1go.png?v=1776235777","url":"https:\/\/www.plcprotech.com\/fr\/products\/e70acmse0204sa1etr-lenze-i700-double-inverter-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}