{"product_id":"e82zafac-lenze-8200-series-standard-i-o-analog-application-module","title":"Module d'application analogique E\/S standard Lenze série 8200 E82ZAFAC","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE82ZAFAC (E82ZAFAC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile I\/O application module designed for the Lenze 8200 Vector and 8200 Motec series of frequency inverters. This module acts as a bridge between the inverter's internal processing and external control hardware, providing a comprehensive array of digital and analog connection points. In industrial B2B applications—such as synchronized multi-drive conveyors, dosing systems, and climate control automation—the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE82ZAFAC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a critical component for integrating local sensors, potentiometers, and PLC signals. By utilizing this module, system engineers can achieve precise closed-loop speed control and complex logic sequences directly at the drive level. Although currently in its phase-out stage, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE82ZAFAC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eremains an essential resource for maintaining the flexibility and connectivity of existing 8200-series installations, offering German-engineered reliability in a compact, modular format.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE82ZAFAC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis architected for \"hot-plug\" integration into the standard AIF (Automation Interface) slot located on the front of the 8200-series drives. The module features a high-density terminal configuration, including 7 digital inputs for sequence control (e.g., start\/stop, clockwise\/counter-clockwise, fixed speeds) and 2 digital outputs for status signaling (e.g., \"Ready\" or \"Fault\" states). The analog section is equally robust, providing 2 analog inputs (0-10V or 0\/4-20mA) for setpoint values or sensor feedback, and 2 analog outputs for visualizing actual values like motor frequency or current on external meters. Its ultra-compact 5 x 1 x 7 cm footprint and lightweight 0.12 kg build allow for maximum functionality without increasing the overall dimensions of the inverter unit.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE82ZAFAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLenze\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8200-series (Vector \/ Motec)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard I\/O \/ Analog Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 Configurable Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Configurable Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 (0-10V, 0\/4-20mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 (0-10V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.12 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Status\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase-Out\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85371091\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I switch the analog inputs between voltage (0-10V) and current (4-20mA) signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe signal type for the analog inputs on the E82ZAFAC is typically determined by internal parameter settings within the 8200-series inverter (such as parameter C0034). Some hardware versions may also require the adjustment of miniature internal DIP switches or jumpers located on the module itself prior to installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the E82ZAFAC compatible with the newer i550 series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The E82ZAFAC is specifically designed for the AIF slot architecture of the 8200-series. Newer Lenze drives like the i550 utilize a different modular interface system. To transition to newer technology, a complete drive and I\/O module upgrade is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the digital inputs for high-speed counting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the digital inputs are optimized for standard control logic and switching, their sample rate is limited by the inverter's internal processing cycle. For high-speed pulse counting or positioning, specialized function modules or the 9300-series are generally recommended.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eFor successful installation of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE82ZAFAC\u003c\/strong\u003e, ensure the inverter is powered down before inserting the module into the AIF slot to prevent electrical transients. When wiring the analog inputs, use shielded twisted-pair cables to protect the low-voltage signals from electromagnetic interference generated by the motor cables. The shield should be grounded at the inverter's shield plate. To prevent signal noise, maintain a separation of at least 10 cm between the I\/O wiring and the high-voltage power cables. Once installed, use the Lenze Global Drive Control (GDC) software or a plug-in keypad to assign the desired functions to the I\/O terminals (e.g., assigning a specific digital input to \"DC Braking\" or an analog output to \"Motor Torque\").\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105067327851,"sku":"E82ZAFAC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82zafac-ale2cfpnyny.png?v=1776235935","url":"https:\/\/www.plcprotech.com\/fr\/products\/e82zafac-lenze-8200-series-standard-i-o-analog-application-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}