{"product_id":"emerson-pr6423-xxx-x4x-con021-epro-eddy-current-proximity-transducer-system","title":"Système de transducteur de proximité à courant de Foucault Emerson PR6423\/XXX-X4X + CON021 EPRO","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Emerson\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEPRO\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries PR6423 and CON021 constitute a complete Eddy Current Proximity Transducer System, engineered for high-precision, non-contacting displacement and vibration measurements. This system is a core component of the CSI 6500 and MMS 6000 Machinery Health Monitors, specifically designed for the protection of critical rotating machinery such as steam\/gas turbines, centrifugal compressors, and boiler feed pumps.\u003c\/p\u003e\n\u003cp\u003eThe system operates by generating a high-frequency electromagnetic field at the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6423 Eddy Current Displacement Transducer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etip. As the distance between the sensor and the metallic shaft changes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021 Eddy Current Signal Converter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edetects variations in the eddy current losses and translates them into a highly linear negative voltage signal. Known for its stability in high-temperature and high-pressure environments, the EPRO PR6423 system is the industry standard for measuring radial shaft vibration, axial thrust position, and shaft eccentricity according to API 670 standards.\u003c\/p\u003e\n\u003ch3\u003eSystem Architecture\u003c\/h3\u003e\n\u003cp\u003eThe measurement string is a factory-calibrated unit consisting of:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePR6423 (Standard 2.0 mm range).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConverter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCON021 (Standard range driver).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterconnect:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated or extension cable matched to an 8-meter (\u003cstrong\u003eX4X\u003c\/strong\u003e) electrical length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel (System)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePR6423\/XXX-X4X + CON021\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson (EPRO Series)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEddy Current Proximity Transducer System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSI 6500 \/ MMS 6000 Machinery Health\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (0.08 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinearity Error\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤ 1.0%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20,000 Hz (-3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal System Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 Meters (Fixed Calibration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-23 VDC to -32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-4 V to -20 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSensor: -35 to 180°C \/ Converter: -30 to 100°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Pressure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,000 hPa (145 psi) at sensor head\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eTo ensure system compatibility and calibration accuracy, the following part number structures are utilized for the EPRO series:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Converter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEddy Current Signal Converter (Standard Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePR6423\/XXX-X4X\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0mm Sensor, 8m Total Length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eX4X\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuffix denoting 8m system calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Notes \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Calibration and Cable Length:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn the EPRO proximity system, the cable is an active part of the tuned oscillator circuit. The CON021 is specifically calibrated for the inductance of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8-meter (X4X)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estring. Shortening the cable will increase sensitivity and decrease the linear range, while lengthening it will decrease sensitivity. Field repairs involving cable splicing are not permitted as they compromise the EMI shielding and system impedance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMagnetic Runout and Target Material:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system is calibrated for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e42CrMo4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esteel. If the target area on the shaft has residual magnetism (magnetic runout) or is made of a different alloy, the CON021 output will include false vibration signals. Ensure the shaft is degaussed and the target surface is concentric to the bearing journals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PR6423 should be mounted in a rigid bracket to prevent \"bracket resonance\" from being misinterpreted as shaft vibration. Use the CON021 output voltage to set the air gap; a reading of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-12.0 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates the sensor is at the electrical center of its 2.0 mm linear range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the PR6423 sensor is hermetically sealed, the Lemo connection between the sensor and extension cable is a common failure point if exposed to oil or moisture. It is mandatory to use the supplied PTFE sealing or an IP65-rated junction box for this connection.\u003c\/p\u003e\n\u003ch3\u003eTroubleshooting \u0026amp; FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I replace a PR6423 sensor without replacing the CON021?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the new sensor has the same total cable length code (e.g., X4X for 8m) as the original, as the CON021 is tuned to the total length, not the individual sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does a constant -0.5V to -1.0V output from the CON021 indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This usually indicates a \"Short Circuit\" or \"Bottom Out\" condition where the sensor is physically touching the shaft or the cable is crushed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does temperature affect the EPRO system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The PR6423 features temperature compensation. However, extreme shifts can cause a zero-point drift of approximately 200 mV \/ 100° K. This is usually negligible for vibration but should be considered for precision thrust position monitoring.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695422337387,"sku":"PR6423\/XXX\/X4X CON021","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-pr6423-xxx-x4x-con021-eddy-current-signal-x3yaold02vt.jpg?v=1766052881","url":"https:\/\/www.plcprotech.com\/fr\/products\/emerson-pr6423-xxx-x4x-con021-epro-eddy-current-proximity-transducer-system","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}