{"product_id":"emerson-ues815s-24a-epro-monitoring-module","title":"Module de surveillance Emerson UES815S-24A Epro","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEpro\u003c\/strong\u003e \u003cstrong\u003eUES815S-24A\u003c\/strong\u003e is a specialized monitoring module engineered for turbomachinery protection and vibration monitoring systems. This high-reliability module provides precision acquisition and conditioning of dynamic speed or pulse signals through its integrated dual-channel frontend architecture. The primary function of the \u003cstrong\u003eUES815S-24A\u003c\/strong\u003e is to process low-level pulse signals and track speed or phase parameters across complex industrial rotating machinery. Featuring automatic or manual trigger level adjustment capability, this device connects seamlessly to standard non-contacting eddy current sensor configurations, serving as an essential processing interface in continuous machinery protection and industrial condition monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEquipped with two independent differential signal inputs dedicated to speed and pulse tracking.\u003c\/li\u003e\n\u003cli\u003eIntegrates automatic and manual trigger level adjustment modes to maintain stable signal identification.\u003c\/li\u003e\n\u003cli\u003ePossesses a high input resistance layout to minimize source signal loading errors.\u003c\/li\u003e\n\u003cli\u003eDelivers direct dynamic signal compatibility with a wide range of standard eddy current displacement measurement networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine speed monitoring and overspeed protection loops.\u003c\/li\u003e\n\u003cli\u003ePhase reference and Keyphasor tracking on high-speed industrial compressors.\u003c\/li\u003e\n\u003cli\u003eDynamic pulse tracking on rotating shafts and machinery gear configurations.\u003c\/li\u003e\n\u003cli\u003eContinuous tachometer input routing within plant-wide asset protection infrastructures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMfr. Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUES815S-24A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUPC \/ GTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10612598124029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo independent differential inputs for pulse sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Sensor Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpro eddy-current type sensor systems PR 6422\/.. to PR 6425\/.. with CON 0.. or PR 9376\/.. or PR 6453\/..\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to + or -27.3 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Permissible Input Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 20000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Level Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual trigger level adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Input Level for Automatic Tracing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 cm x 22 cm x 7.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.74 KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Interfacing:\u003c\/strong\u003e Wire the dynamic pulse or eddy current sensor output directly to the independent differential inputs using properly shielded twisted-pair cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e Terminate cable shields cleanly at the designated system reference ground point to eliminate electrostatic noise injection across high-frequency pulse paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrigger Threshold Configuration:\u003c\/strong\u003e Set the tracing configuration to automatic mode for signals exceeding 2 V, or implement a manual trigger level if source signal fluctuations demand fixed threshold clamping.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695189029227,"sku":"UES815S-24A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-ues815s-24a-monitoring-module-gh2k2go45ei_de4afd55-0998-4eeb-ba85-f961ab93a2d4.jpg?v=1766114562","url":"https:\/\/www.plcprotech.com\/fr\/products\/emerson-ues815s-24a-epro-monitoring-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}