{"product_id":"emerson-ve3008-kj2005x1-mq2-deltav-mq-controller","title":"Contrôleur DeltaV MQ Emerson VE3008 KJ2005X1-MQ2","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KJ2005X1-MQ2\u003c\/strong\u003e (also referred to as \u003cstrong\u003eVE3008\u003c\/strong\u003e) is a high-performance \u003cstrong\u003eMQ Controller\u003c\/strong\u003e designed for the DeltaV scalable process system. This \u003cstrong\u003econtroller\u003c\/strong\u003e serves as a core processing unit responsible for executing control strategies and managing communication within the automation network. It is engineered for reliable operation in demanding industrial environments and is suitable for installation in hazardous locations when specific safety guidelines are followed.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed processing for control strategy execution\u003c\/li\u003e\n\u003cli\u003eScalable architecture for process system integration\u003c\/li\u003e\n\u003cli\u003eDesigned for operation in hazardous atmospheres (Class I, Division 2)\u003c\/li\u003e\n\u003cli\u003eIntegrated communication capabilities for DeltaV system connectivity\u003c\/li\u003e\n\u003cli\u003eCompliant with ISA-S71.04-1985 airborne contaminants standards (Class G3)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS)\u003c\/li\u003e\n\u003cli\u003eIndustrial process automation and management\u003c\/li\u003e\n\u003cli\u003eScalable process control applications\u003c\/li\u003e\n\u003cli\u003eHazardous location control environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ2005X1-MQ2 (VE3008)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e+5 VDC at 1.4 A (Local Bus Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e10g 1\/2 Sinewave for 11msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e1mm Peak to Peak from 2 to 13.2Hz; 0.7g from 13.2 to 150Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirborne Contaminants\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThis unit cannot be removed or inserted with system power energized unless the area is known to be non-hazardous.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding to comply with EMI\/RFI mitigation standards.\u003c\/li\u003e\n\u003cli\u003eThe device must not be connected to sources generating potentials in excess of 60 VAC or 75 VDC under normal conditions.\u003c\/li\u003e\n\u003cli\u003eRefer to document 12P2046 \"DeltaV Scalable Process System Zone 2 Installation\" for comprehensive instructions regarding installation, removal, and operation in hazardous areas.\u003c\/li\u003e\n\u003cli\u003eThe unit contains no user-serviceable parts and should not be disassembled. Calibration is not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX: II 3G Ex ec IIC Gc (FM19ATEX0173U)\u003c\/li\u003e\n\u003cli\u003eIECEx: IECEX FMG 19.0019U\u003c\/li\u003e\n\u003cli\u003eFM: CL. I Div. 2 GP. A, B, C, D; CL. I Zone 2 AEx\/Ex ec IIC Gc (FM17US0286U)\u003c\/li\u003e\n\u003cli\u003eCE: Approved\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695183458667,"sku":"VE3008 KJ2005X1-MQ2 13P0072X092","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-ve3008-kj2005x1-mq2-13p0072x092-digital-input-module-bqyliiblvqu_9f76c7ff-369d-49d5-b213-3e2e6ae6275c.jpg?v=1766114377","url":"https:\/\/www.plcprotech.com\/fr\/products\/emerson-ve3008-kj2005x1-mq2-deltav-mq-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}