{"product_id":"emerson-vim-4201-deltav-virtual-i-o-module","title":"Module E\/S Virtuel Emerson VIM-4201","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson\u003c\/strong\u003e \u003cstrong\u003eVIM-4201\u003c\/strong\u003e is a Virtual I\/O Module network gateway designed to provide a native DeltaV I\/O interface to open plant Ethernet networks and devices. This module enables DeltaV Controllers to read and write signals from plant floor devices operating on Ethernet networks, including programmable logic controllers (PLCs), Motor Control Centers, and weigh scales. The \u003cstrong\u003eVIM-4201\u003c\/strong\u003e is specifically designed for redundant installations, allowing two modules to be set up as a redundant pair to provide backup plant network capabilities. It emulates DeltaV Serial Cards, allowing seamless integration where the DeltaV Controller auto-senses the gateway directly within the DeltaV system architecture.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmulates up to 4 DeltaV Serial Cards and supports up to 128 Serial Card Datasets.\u003c\/li\u003e\n\u003cli\u003eProvides automated integration with the DeltaV auto-sense I\/O function.\u003c\/li\u003e\n\u003cli\u003eSupports 1:1 module redundancy with automatic or manual switchover capabilities managed via DeltaV Diagnostics.\u003c\/li\u003e\n\u003cli\u003eEquipped with a standard 10BaseT 8-pin RJ-45 connector for external plant Ethernet interface.\u003c\/li\u003e\n\u003cli\u003eFeatures an intuitive setup interface through the VIMNet Explorer Utility with graphical drag-and-drop network configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRedundant network gateway mirroring for open plant Ethernet networks.\u003c\/li\u003e\n\u003cli\u003eInterfacing DeltaV Controllers with plant floor PLCs.\u003c\/li\u003e\n\u003cli\u003eMotor Control Center status monitoring and control data routing.\u003c\/li\u003e\n\u003cli\u003eProcess weigh scale integration over Modbus TCP\/IP or EtherNet\/IP protocols.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVIM-4201\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDeltaV Virtual I\/O Module for Redundant Installations\u003c\/strong\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMIM-4207\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeltaV Virtual I\/O Module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIOD-4101\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP Master Driver for DeltaV VIM \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIOD-4102\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet\/IP Scanner Driver for DeltaV VIM \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIOD-4104\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneric Device Ethernet \/ IP Scanner Driver for DeltaV VIM \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupplied by System Power Supply through 2-wide Power\/Controller Carrier \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 A, non-replaceable fuses \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 W typical, 5.4 W maximum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVIM User Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 MB \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Network Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne 10BaseT 8-pin RJ-45 Connector \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmulated Cards Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Emulated DeltaV Serial Cards \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDataset Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128 data sets per VIM (32 per Emulated Card) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNode Capacity (Redundant Mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 slaves only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC (32 to 140 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC (-40 to 185 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirborne Contaminants\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Airborne Contaminants Class G2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 g, 1\/2-sine wave for 11 ms \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak from 5 Hz to 16 Hz, 0.5 g from 16 Hz to 150 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eLED Indicator\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eON Status Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGreen -- Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates DC power is applied \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRed -- Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates an error condition \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGreen -- Active\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates that the VIM is commissioned and active \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGreen -- Standby\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot used \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eYellow Flashing -- Network\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates valid network communication \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eYellow Flashing - Ctlr I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicates valid DeltaV I\/O Bus communication \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Location:\u003c\/strong\u003e Install the module on its own 2-wide carrier to the left-hand-side of the DeltaV controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Provision:\u003c\/strong\u003e Ensure each module is supported by a dedicated system power supply connected via the carrier side connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Wiring:\u003c\/strong\u003e Establish communication connections to the plant Ethernet network using the integrated RJ-45 Ethernet port on the module face.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Configuration:\u003c\/strong\u003e Wire the primary and standby modules such that they can monitor each other continuously with status commands across the common Ethernet Network.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52695191585131,"sku":"VIM-4201","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/emerson-vim-4201-virtual-i-o-module-zyribt1w2ad_fce45c1c-880e-49c7-9736-cd5e154a9f26.jpg?v=1766114650","url":"https:\/\/www.plcprotech.com\/fr\/products\/emerson-vim-4201-deltav-virtual-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}