{"product_id":"ep1008-0002-beckhoff-ethercat-box-8-channel-digital-input-module","title":"EP1008-0002 BECKHOFF Boîtier EtherCAT Module d'entrée numérique 8 canaux","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEP1008-0002 (EP10080002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands as a high-performance EtherCAT Box designed for direct field integration without the need for a protective control cabinet. This 8-channel digital input module is engineered to capture binary control signals from the process level and transmit them, with electrical isolation, to the higher-level automation controller. Optimized for decentralized architectures in harsh industrial environments such as automotive assembly lines, high-speed packaging, and heavy machinery, this module significantly reduces wiring complexity and minimizes signal latency. By providing local 24 VDC sensor power and featuring a robust IP67-rated housing, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEP1008-0002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures maximum system uptime and operational reliability in mission-critical applications where space and environmental resistance are paramount.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture of the EP1008-0002 is built on the high-speed EtherCAT protocol, enabling synchronized data acquisition across large-scale distributed systems. The module features eight digital inputs compliant with EN 61131-2 (Type 1\/3) standards, utilizing a 3.0 ms input filter to suppress electrical noise and debounce mechanical contact signals effectively. Connection is established via industry-standard M12 5-pin circular connectors, which provide a secure, vibration-proof interface for sensors. Power distribution is managed through a dedicated M8 feed and downstream connection system, allowing for efficient \"daisy-chaining\" of multiple boxes. The internal circuitry is electrically isolated up to 500 V, protecting the main EtherCAT network segment from potential field-side surges or ground loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEP1008-0002\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBECKHOFF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEtherCAT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Digital Inputs (Type 1\/3)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (-15 percent \/ +20 percent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Filter Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Voltage \"0\"\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-3 to +5 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Voltage \"1\"\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11 to 30 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 mA from US\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM12 x 1 (Inputs), M8 (Power\/Bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePA6 Polyamide\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP65, IP66, IP67\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e165 g (approx.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 mm x 126 mm x 26.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the EP1008-0002 handle sensor power supply in a short-circuit scenario?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module derives sensor power from the control voltage (US). It is equipped with short-circuit proof protection for the total sensor supply, with a maximum current limit of 0.5 A. If a fault occurs at the sensor level, the module prevents the fault from damaging the internal electronics or interrupting the primary EtherCAT communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between the EP1008-0002 and standard EP1008 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe -0002 variant specifically utilizes M12 input connectors (5-pin, a-coded) rather than the smaller M8 connectors found on standard models. This allows for the use of standard M12 sensor cables which are often preferred in heavy-duty industrial environments for their mechanical durability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module suitable for explosive atmospheres or hazardous locations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the EP1008-0002 carries ATEX certification with the Ex marking II 3 G Ex nA IIC T4 Gc. This confirms its suitability for use in Zone 2 hazardous areas, provided it is installed according to the specific safety requirements for non-sparking equipment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure maximum EMC immunity in high-interference environments, always use shielded M8 cables for the EtherCAT bus interface. The screw-type connectors must be tightened to the specified torque (typically 0.4 Nm for M8 and 0.6 Nm for M12) to maintain the IP67 seal and ensure a reliable ground path through the connector housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the module is rated for up to 60 deg C, avoid mounting the device in direct contact with heat-generating machinery or in stagnant air pockets. Vertical mounting is recommended to facilitate natural convection. Ensure that the total current draw for all 8 sensors does not exceed the 0.5 A limit to prevent thermal tripping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen daisy-chaining power via the M8 downstream connectors, calculate the total voltage drop across the chain. For long cable runs, verify that the terminal voltage at the last module remains within the 24 VDC (-15 percent) tolerance to prevent intermittent input signal failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106658869611,"sku":"EP1008-0002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ep1008-0002-dpilcp55qzn.png?v=1776244629","url":"https:\/\/www.plcprotech.com\/fr\/products\/ep1008-0002-beckhoff-ethercat-box-8-channel-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}