{"product_id":"evs9329-epv004-lenze-9300-series-30-kw-servo-position-controller","title":"Contrôleur de position servo Lenze EVS9329-EPV004 série 9300 30 kW","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEVS9329-EPV004 (EVS9329-EPV004)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty servo position controller from the high-performance Lenze 9300-Series, engineered for precision motion control in complex industrial automation architectures. With a substantial power rating of 30.0 kW, this drive is a vital component for high-torque applications in sectors such as metal forming, large-scale printing, and heavy-duty material handling. Designed to provide exceptional dynamic response, the controller excels in reducing cycle times and eliminating mechanical stress through smooth, precise positioning profiles. Although currently in the phase-out stage, its proven reliability and IP20-rated hardware continue to make it a critical replacement part for maintaining high-availability production lines and preventing costly unscheduled downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe EVS9329-EPV004 architecture is centered on a high-speed digital signal processor (DSP) capable of managing complex positioning tasks, including synchronized multi-axis motion and electronic gearing. The \"EP\" designation indicates its integrated positioning control functionality, which allows the drive to handle path control independently, reducing the processing load on the central PLC. The unit is housed in a robust IP20 enclosure, optimized for vertical mounting within electrical cabinets. It features a sophisticated thermal management system to handle the heat dissipation associated with 30.0 kW power conversion. Furthermore, the 9300-series platform supports versatile feedback systems and fieldbus communication, ensuring seamless integration into existing legacy systems while maintaining compatibility with high-resolution motor feedback protocols.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEVS9329-EPV004\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLenze\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9300-Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eServo Position Controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30.0 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35.00 x 25.00 x 25.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.50 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Phase\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase-Out\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 45 deg C (refer to manual for derating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85044095\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExport Control\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eECCN N\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary considerations for replacing a failed EVS9329-EPV004 in a legacy system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince this model is in the phase-out stage, ensure that the parameter set from the original unit is backed up using Lenze Global Drive Control (GDC) software. Hardware-wise, verify that the existing cooling infrastructure can accommodate the 30.0 kW heat load and that the feedback cables are compatible with the specific EVS9329 interface version.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this servo controller support integrated safety functions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 9300-series typically utilizes external safety relays for Safe Torque Off (STO) functions. However, specific configurations may include \"Safe Stop\" features depending on the sub-module installed. It is recommended to check the specific terminal strip configuration of the EPV004 variant to confirm local safety logic wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the EVS9329-EPV004 be used for simple speed control instead of positioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the \"EP\" version is specialized for positioning, it is fully backward compatible with standard speed and torque control modes. The internal function blocks can be reconfigured via software to bypass positioning loops if only basic velocity control is required for a 30.0 kW application.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management and Airflow:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDue to the high 30.0 kW power rating, the EVS9329-EPV004 generates significant heat at full load. Ensure a minimum clearance of 150 mm above and below the unit. If installing multiple drives, forced ventilation in the cabinet is mandatory to maintain an ambient temperature below 45 deg C, preventing the drive from entering thermal protection mode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Shielding for High Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo mitigate electromagnetic interference (EMI) at high power levels, use a high-frequency (HF) low-impedance ground strap to connect the drive chassis to the mounting plate. All motor cables must be 360-degree shielded at the drive's PE rail. Improper grounding at this power level can lead to encoder signal corruption and intermittent \"External Fault\" trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Bus Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen servicing the unit, be aware that the internal capacitors store lethal energy. After disconnecting the mains power, wait at least 10 to 15 minutes and use a multimeter to verify that the DC bus voltage (terminals +UG, -UG) has dropped below 50 VDC before touching any terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105061429611,"sku":"EVS9329-EPV004","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9329-epv004-1bbipjrrspr.png?v=1776236737","url":"https:\/\/www.plcprotech.com\/fr\/products\/evs9329-epv004-lenze-9300-series-30-kw-servo-position-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}