{"product_id":"fc-051pk18s2e20h3xxcxxxsxxx-danfoss-vlt-micro-drive-0-18kw-vfd","title":"Variateur micro VLT 0.18kW VFD Danfoss FC-051PK18S2E20H3XXCXXXSXXX","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-051PK18S2E20H3XXCXXXSXXX (FC-051PK18S2E20H3XXCXXXSXXX)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an ultra-compact frequency converter from the Danfoss VLT® Micro Drive FC 051 series, specifically engineered for low-power applications at 0.18 kW (0.25 hp). This single-phase 200-240 VAC drive is designed for high-density integration in small machinery, providing precise motor control with a minimal footprint. Despite its small M1 frame size, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-051PK18\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes professional features like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCoated PCBs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor environmental protection and an integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eH3 RFI filter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Class A1\/B) to ensure electromagnetic compatibility in commercial and industrial settings. It is the ideal solution for controlling small fans, pumps, and conveyor belts where reliability and energy efficiency are required in a chassis-mount format.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model code\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-051PK18S2E20H3XXCXXXSXXX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifies a precise hardware configuration tailored for small-scale automation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFC-051\u003c\/strong\u003e: Part of the VLT® Micro Drive series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePK18\u003c\/strong\u003e: Designates a power rating of 0.18 kW (0.25 hp).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eS2\u003c\/strong\u003e: Single-phase input for 200-240 VAC mains voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eE20\u003c\/strong\u003e: IP20 \/ Chassis enclosure rating, requiring panel mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eH3\u003c\/strong\u003e: Integrated RFI Filter Class A1\/B (Category C1) for maximum noise suppression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX (Brake)\u003c\/strong\u003e: No integrated brake chopper.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX (LCP)\u003c\/strong\u003e: Supplied without a Local Control Panel (must be ordered separately).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eC\u003c\/strong\u003e: Conformal Coating on PCBs for resistance against dust and moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSXXX\u003c\/strong\u003e: Equipped with the latest standard software release.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eM1\u003c\/strong\u003e: The most compact frame size in the FC 051 series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-051PK18S2E20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.18 kW \/ 0.25 hp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 - 240 VAC (Single-phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 100% of supply voltage (3-phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRFI Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass A1\/B (C1) Integrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePCB Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coating (Class 3C3)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 50 deg C (with derating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 1.1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I program the drive if it is supplied without an LCP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-051PK18\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequires an external Local Control Panel (LCP 11 or LCP 12) for manual parameter adjustment. Alternatively, you can use the Danfoss MCT 10 setup software via a PC interface. This \"no LCP\" version is cost-effective for high-volume OEMs who pre-program drives before shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this single-phase drive control a standard three-phase motor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-051PK18\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etakes single-phase 230V input and converts it to a pulse-width modulated (PWM) three-phase 230V output. This allows you to run industrial three-phase motors (wired in Delta for 230V) in locations where only single-phase power is available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat environments is the \"Coated PCB\" version suitable for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"C\" suffix indicates that the internal circuit boards are coated to protect against humidity, salt air, and conductive dust. This makes the drive suitable for use in environments like commercial kitchens, greenhouses, or small-scale industrial workshops where airborne contaminants are present.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eM1 Frame Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe M1 frame is designed for DIN-rail or backplate mounting. To ensure proper thermal management, maintain at least 100 mm of clearance above and below the unit. Side-by-side mounting is supported without derating, allowing for maximum cabinet space utilization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI\/RFI Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo achieve the benefits of the H3 Class A1\/B filter, you must use shielded motor cables. The shield should be connected to the metal decoupling plate of the drive using the provided 360-degree clamps. This is essential for preventing interference with nearby sensors or household electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommissioning for Low Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen configuring the 0.18 kW drive, ensure the Motor Current (Parameter 1-24) is set accurately. Because the current is very low, even small deviations can lead to poor torque performance or false \"No Motor\" alarms. Perform an Automatic Motor Adaptation (AMA) for the best results.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102416232811,"sku":"FC-051PK18S2E20H3XXCXXXSXXX","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fc-051pk18s2e20h3xxcxxxsxxx-4irph1ir2ly.png?v=1776137395","url":"https:\/\/www.plcprotech.com\/fr\/products\/fc-051pk18s2e20h3xxcxxxsxxx-danfoss-vlt-micro-drive-0-18kw-vfd","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}