{"product_id":"fc-302p3k7t2e20h2xxxxxxsxxxxaxbxcxxxxdx-danfoss-vlt-automationdrive-fc-302","title":"Variateur d'automatisation VLT FC 302 Danfoss FC-302P3K7T2E20H2XXXXXXSXXXXAXBXCXXXXDX","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-302P3K7T2E20H2XXXXXXSXXXXAXBXCXXXXDX (131B0287)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, heavy-duty frequency converter from the Danfoss VLT® AutomationDrive FC 302 series. Rated for 3.7 kW (5.0 HP) at 200-240V, this drive is engineered for the most demanding industrial automation tasks, offering exceptional control over any motor technology, including permanent magnet and asynchronous motors. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-302P3K7T2E20H2XXXXXXSXXXXAXBXCXXXXDX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to maximize uptime in high-torque applications such as cranes, extruders, and complex conveyor systems. Its advanced hardware architecture, including the integrated H2 RFI filter and the robust A3 frame size, ensures reliable operation in environments requiring strict electromagnetic compatibility and precise motion control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe FC 302 series is the top-tier platform in the VLT portfolio, characterized by its modularity and high-speed processing capabilities.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower \u0026amp; Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for 3.7 kW \/ 5.0 HP output with a three-phase input range of 200 - 240 VAC, making it ideal for regions or facilities with low-voltage industrial grids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures an integrated H2 RFI filter, which ensures the drive meets industrial-grade electromagnetic interference standards, protecting sensitive sensors and communication lines nearby.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing the A3 frame size with an IP20 rating, this chassis-based unit is designed for efficient heat dissipation within a controlled electrical cabinet environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile currently configured with standard \"X\" options (No LCP, No Brake Chopper), the FC 302 platform allows for extensive future scalability via A, B, C, and D option slots for advanced networking and functional safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAt a net weight of 5.91 kg, the drive features a high-grade aluminum and plastic construction designed for long-term vibration resistance and thermal stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-302P3K7T2E20H2XXXXXXSXXXXAXBXCXXXXDX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e131B0287\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.7 kW \/ 5.0 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 - 240 VAC (3-Phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eA3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRFI Filter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH2 Class\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrake Chopper\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone (X)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePCB Coating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard (Not Coated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.91 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I upgrade this drive to include a display and manual control later?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Since the LCP (Local Control Panel) slot is marked \"X,\" you can purchase a separate LCP 102 (Graphical) or LCP 101 (Numerical) display and hot-plug it into the front of the drive for local commissioning and diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the H2 RFI filter in this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe H2 filter (RFI Class A2) allows for the use of shielded motor cables up to 50 meters (150 meters unshielded) while maintaining compliance with industrial EMC limits. This prevents the drive from interfering with other electronic components on the same power bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this drive suitable for applications requiring dynamic braking?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific configuration (Suffix X for Brake) does not include a built-in brake chopper. If your application involves fast deceleration or overhauling loads (like a hoist), you should consult with a technician to determine if an external braking module or a different FC 302 configuration with a \"B\" suffix is required.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling and Clearance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe A3 frame size relies on vertical airflow for cooling. Ensure a minimum of 100 mm (4 inches) of free space above and below the unit. The FC 302 supports side-by-side mounting without derating, allowing for maximum density in your control panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding for EMC:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo fully utilize the integrated H2 RFI filter, you must use a shielded motor cable. The shield must be connected to the metal decoupling plate of the drive using a 360 degree clamp. This creates a low-impedance path for high-frequency noise, ensuring stable operation of nearby PLC and communication modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Wiring Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways separate the high-voltage mains\/motor cables from the low-voltage control and communication wiring. Use separate cable ducts or maintain a distance of at least 200 mm to prevent cross-talk and erratic signal behavior in the analog and digital inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102414758251,"sku":"FC-302P3K7T2E20H2XXXXXXSXXXXAXBXCXXXXDX","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fc-302p3k7t2e20h2xxxxxxsxxxxaxbxcxxxxdx-rt431jcrcux.png?v=1776137403","url":"https:\/\/www.plcprotech.com\/fr\/products\/fc-302p3k7t2e20h2xxxxxxsxxxxaxbxcxxxxdx-danfoss-vlt-automationdrive-fc-302","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}