{"product_id":"foxboro-fbm217-p0914tr-discrete-input-module","title":"Module d'entrée discrète Foxboro FBM217 (P0914TR)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM217 (P0914TR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, 32-channel Discrete Input Module designed for the Foxboro I\/A Series and EcoStruxure Foxboro DCS. It serves as the primary interface for monitoring digital field signals, such as dry contacts or DC voltage sources from pushbuttons, limit switches, and motor starter auxiliary contacts.\u003c\/p\u003e\n\u003cp\u003eIn industrial automation, the FBM217 is recognized for its versatility; depending on the associated Terminal Assembly (TA), it can monitor a wide range of voltages, including 24 V DC, 125 V DC, 120 V AC, or 240 V AC. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0914TR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesignation refers to the specific hardware assembly of the module, which is engineered for high-availability process control in demanding environments like power generation and chemical manufacturing.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe FBM217 architecture is optimized for group isolation and redundant signal processing:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides 32 discrete input channels in a compact \"plug-in\" form factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan be deployed as a single unit or as a redundant pair. When configured in a pair, the modules provide \"bumpless\" switchover, ensuring that a single module failure does not interrupt the monitoring of critical process interlocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConverts field-side electrical signals (voltage or contact state) into digital data for the Field Control Processor (FCP) via the redundant 2 Mbps or 10 Mbps Fieldbus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGroup Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 32 channels are group-isolated from the internal system logic, providing a robust buffer against field-side electrical noise and transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFBM217\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eP0914TR\u003c\/strong\u003e (Housed Module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete Input (Voltage Monitor or Contact Sense)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC Group Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +70°C (-4 to +158°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95% (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eISA-S71.04 Class G3 (Conformal Coated)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Area\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX Zone 2 \/ Class I, Div 2 Certified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the difference between FBM217 and P0914TR?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM217\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the functional model name used in DCS software and system design.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0914TR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the specific hardware part number for the module assembly. They refer to the same physical unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does this module require an external power source for the inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: It depends on the application. For \"Contact Sense,\" the module\/TA provides the wetting voltage. For \"Voltage Monitor,\" the module monitors an external DC or AC source provided by the field device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the FBM217 be hot-swapped?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes. The FBM217 supports full hot-pluggable capability. On a redundant baseplate, a failed module can be removed and replaced without powering down the system or losing signal visibility.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBaseplate Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FBM217 (P0914TR) must be installed on a 200 Series Modular Baseplate (e.g.,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRH924YF\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0926KE\u003c\/strong\u003e). Ensure the locking handles are fully engaged to secure the module to the Fieldbus pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFilter Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent \"contact bounce\" from mechanical switches, engineers should configure the input filter time (software-selectable) to ensure stable signal detection in the DCS logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Assembly (TA) Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FBM217 must be paired with the correct TA (e.g.,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0916BT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor 24V DC contact sense) and the appropriate termination cable (\u003cstrong\u003eP0926GQ\u003c\/strong\u003e) to match the specific field voltage requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe FBM217's\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3-rated conformal coating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a critical engineering advantage, protecting the internal electronics from corrosion caused by sulfur dioxide (\u003cspan class=\"math-inline\"\u003eSO2\u003c\/span\u003e) and hydrogen sulfide (\u003cspan class=\"math-inline\"\u003eH2S\u003c\/span\u003e). Its ability to handle 32 channels in a single slot significantly reduces the footprint in the I\/O cabinet, while its support for millisecond-precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSequence of Events (SOE)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erecording is vital for post-trip analysis in safety-critical systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":52695403299179,"sku":"FBM217 P0914TR","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/foxboro-fbm217-p0914tr-discrete-input-module-jao4hdlke5a_9687ec8b-c880-48a9-b491-22fcad689480.jpg?v=1766133890","url":"https:\/\/www.plcprotech.com\/fr\/products\/foxboro-fbm217-p0914tr-discrete-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}