{"product_id":"ge-fanuc-ic693bem341-series-90-30-fip-bus-controller","title":"Contrôleur de bus FIP série 90-30 GE Fanuc IC693BEM341","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693BEM341 \u003c\/strong\u003eis a high-performance FIP (Factory Instrumentation Protocol) Bus Controller designed for the GE Fanuc Series 90-30 PLC ecosystem. Serving as a critical communication bridge, this 2.5 MHz version facilitates high-speed deterministic data exchange in demanding industrial environments such as power generation, water treatment, and large-scale manufacturing. By upgrading the network speed from the previous 1.0 MHz standard, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693BEM341\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eminimizes network latency and ensures real-time synchronization across distributed I\/O nests and slave devices. Its integration is vital for reducing system-wide downtime and maintaining data integrity in complex automated architectures.\u003c\/p\u003e\n\u003ch3\u003eFunctional Capabilities \u0026amp; Architecture\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693BEM341\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintroduces Mode 30 configuration, a significant evolution from the legacy Mode 11. This operational mode transforms the controller into a robust management hub capable of handling redundancy and complex messaging services.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnhanced system availability through redundant controller configurations, essential for mission-critical processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlave Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull oversight of I\/O nests, drives, and control stations, allowing for centralized monitoring and diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTime Stamping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrecise event logging for up to 1024 Boolean values, utilizing the POSIX COMV format for standardized chronological tracking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSynchronous Exchange:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eImplementation of MPS (Message Periodic\/Sporadic) services ensures that produced and consumed data remain perfectly aligned with the PLC scan cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC693BEM341\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries 90-30\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFIP (WorldFIP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCPU Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC693 PLC CPU Release 8.10 or greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration Tools\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFBCLOAD Utility, HHP, or IC641CTLxxx Rel 2.0+\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the IC693BEM341 differ from the IC693BEM340?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe primary difference is the network transmission speed. The BEM341 operates at 2.5 MHz, whereas the BEM340 is limited to 1.0 MHz. While they are functionally identical in terms of logic, the BEM341 requires a more recent CPU firmware (Release 8.10 or higher) to operate correctly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use standard IC641SWPxxx software to configure this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This version of the FIP Bus Controller is not compatible with IC641SWPxxx programming software. You must use the Hand-Held Programmer (HHP), Windows-based IC641CTLxxx Release 2.0 or later, or the FBCLOAD configuration utility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the new Mode 30 functionality?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMode 30 is an extension of Mode 11 that adds critical industrial features including hardware redundancy, management of slave devices (nests and drives), and the ability to receive external configurations directly through the FIP network.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore installing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693BEM341\u003c\/strong\u003e, verify that your Series 90-30 CPU is updated to at least Release 8.10. Failure to meet this minimum firmware requirement will result in configuration errors or a \"Loss of Module\" fault in the PLC hardware software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAt 2.5 MHz, signal integrity is highly sensitive to impedance mismatches. Ensure that proper FIP-standard terminators are installed at both physical ends of the bus to prevent signal reflection and data corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilizing Mode 30 for redundant applications, ensure the FBCLOAD external configuration loader is Version 2.0 or higher. Previous versions of the loader are incompatible with the specific time-stamping and subscriber-type updates required for modern FIP Device Manager specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695413555563,"sku":"IC693BEM341","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ic693bem341-fip-bus-controller-3e5roshshhw_9fb4745b-2105-4dc2-9333-5233c6194595.jpg?v=1766135153","url":"https:\/\/www.plcprotech.com\/fr\/products\/ge-fanuc-ic693bem341-series-90-30-fip-bus-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}