{"product_id":"ge-fanuc-ic695psd140-pacsystems-rx3i-multi-purpose-power-supply","title":"Alimentation polyvalente PACSystems RX3i GE Fanuc IC695PSD140","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003emulti-purpose power supply\u003c\/strong\u003e module operates as a dedicated chassis power distribution source designed for high-availability industrial systems. The \u003cstrong\u003eIC695PSD140\u003c\/strong\u003e converts an unregulated input voltage range from 18 to 30 VDC into three stable output rails to drive internal backplane logic and field-side components. Engineered for structural compatibility with the \u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e hardware platform, this component interfaces directly inside a universal backplane assembly, providing power delivery for process logic controllers and expansion rack nodes. The unit supports advanced configuration arrangements including load-sharing networks and active redundancy deployments, making it suitable for critical infrastructure applications such as power plant distribution, automotive assembly rows, and continuous wastewater processing plants.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides three internal voltage outputs: a +5.1 VDC rail, a +3.3 VDC rail, and a +24 VDC output dedicated to powering external relay module circuits.\u003c\/li\u003e\n\u003cli\u003eSupports dual-redundant or load-sharing multi-module installation with up to four identical supplies operating in a single backplane assembly.\u003c\/li\u003e\n\u003cli\u003eEquipped with front-facing diagnostics including dedicated status LEDs for power indication, generic hardware faults, internal overtemperature, and load circuit exceptions.\u003c\/li\u003e\n\u003cli\u003eFeatures an integrated hardware latching design that switches the module completely off during overload conditions to protect adjacent processing units.\u003c\/li\u003e\n\u003cli\u003eContains a physical front-panel toggle switch situated behind a protection door to toggle supply outputs without interrupting incoming line utility feeds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRedundant Power Distribution Enclosures\u003c\/li\u003e\n\u003cli\u003ePACSystems RX3i Main and Expansion Chassis Platforms\u003c\/li\u003e\n\u003cli\u003eLoad-Sharing Control System Nodes\u003c\/li\u003e\n\u003cli\u003eHigh-Density Field Output Relay Driver Arrays\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration and Rating Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIC695PSD140 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-Purpose Power Supply \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Rated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Watts maximum at full load \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 Watts total (5.1 VDC and 3.3 VDC combined rails) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5.1 VDC Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 6 Amps (30 Watts maximum) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3.3 VDC Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 9 Amps (30 Watts maximum) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Amps maximum for a 100 millisecond duration \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Ripple and Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mV maximum on all output paths \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRide-Through Interruption Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum duration \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Barrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent Safety Thresholds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.1 VDC limited to 7 Amps; 3.3 VDC limited to 10 Amps \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Terminal Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccommodates 14 AWG to 24 AWG copper wire paths \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 Amps max \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Rack Grouping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4 modules per Universal Backplane assembly \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Alignment Mark\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Wiring Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive DC Input Terminal Link 1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive DC Input Terminal Link 2 (Daisy-Chain Option) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative DC Input Terminal Link 1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative DC Input Terminal Link 2 (Daisy-Chain Option) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Symbol (Top)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCore Frame Ground Enclosure Reference Connection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Symbol (Bottom)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSecondary Internal Protection Return Path \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Symbol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal MOV Disconnect Overvoltage Link Point \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Backplane Seating\u003c\/strong\u003e: Align the supply module rails directly into the dedicated slot guides of a PACSystems RX3i Universal Backplane. Slide the module firmly backward until the rear connector is entirely mated with the backplane connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring and Torque\u003c\/strong\u003e: Strip incoming 14 to 22 AWG copper field wires rated for 75 degC environments. Insert a single conductor into each block cage and tighten the integrated screw terminals to a standard torque specification of 0.5 N-m (4.4 in-lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Polarity Alignment\u003c\/strong\u003e: When grouping multiple modules onto a single external DC source, maintain identical connection polarity across every active supply. Any difference in ground or input line potential will cause machine damage or immediate fault trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection Disconnect\u003c\/strong\u003e: For system Hi-pot testing routines, remove the user-installed jumper strap that bridges the lower terminal path to frame ground. Reinstall this grounding strap immediately after testing to restore internal surge protection loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695411491179,"sku":"IC695PSD140","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ic695psd140-pacsystems-rx3i-power-supply-module-bgwvm1eoa5y_e11501e4-975d-4c6e-aaeb-b679cb961207.jpg?v=1766135078","url":"https:\/\/www.plcprotech.com\/fr\/products\/ge-fanuc-ic695psd140-pacsystems-rx3i-multi-purpose-power-supply","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}