{"product_id":"ge-fanuc-pacsystems-rx3i-ic695psa040-power-supply-module","title":"Module d'alimentation GE Fanuc PACSystems RX3i IC695PSA040","description":"\u003ch3\u003eSystem-Level Overview \u0026amp; Operational Value\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695PSA040 (IC695PSA040)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-efficiency 40-Watt power supply module engineered for the GE PACSystems RX3i platform. Operating from universal input voltage ranges of 85 to 264 VAC or 100 to 300 VDC, this module supplies steady power distribution directly across the backplane to drive local processing and I\/O assets. Industrial operations inside automated water treatment plants, chemical processing facilities, and manufacturing assembly lines rely on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695PSA040 (IC695PSA040)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto secure predictable controller execution under fluctuating grid supply conditions. The power supply module isolates internal rack electronics from field electrical noise, logs predictive faults directly to the CPU tables during thermal or load stress, and maintains an integrated ride-through capability. This architectural resilience prevents sudden PLC drops, protects critical runtime parameters, and significantly cuts costly unplanned facility downtime.\u003c\/p\u003e\n\u003ch3\u003eArchitectural Infrastructure \u0026amp; Internal Protection\u003c\/h3\u003e\n\u003cp\u003eThe hardware topology of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695PSA040\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule centers on localized triple-rail output management and automatic electronic protection.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTriple-Rail Voltage Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndependently delivers +5.1 VDC and +3.3 VDC to satisfy RX3i system-level module demands, alongside a dedicated +24 VDC relay output path to power external output relay modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eActive Overcurrent Controls:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures built-in electronic current limiting that caps the 5.1 VDC rail at 7 Amps and the 3.3 VDC rail at 10 Amps. Under overload or short-circuit faults, the supply shuts down automatically and initiates continuous auto-restart attempts until the underlying field fault is cleared.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Status Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHosts an array of four frontline LED status indictors coupled to internal diagnostic relays that broadcast real-time overtemperature, overload, and internal component health directly to the central CPU fault logger.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Data \u0026amp; Hardware Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Index\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC695PSA040\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand Identifier\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE PACSystems (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl System Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRX3i Controllers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Rated Output Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 Watts maximum total\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120\/240 VAC or 125 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAC Input Range Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 to 264 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC Input Range Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 to 300 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70 Watts maximum at full load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current Threshold\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Amps for 250 milliseconds maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Output Specs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.1 VDC (0 to 6 Amps), 3.3 VDC (0 to 9 Amps), 24 VDC (0 to 1.6 Amps)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Boundaries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.1 VDC (5.0 to 5.2 VDC), 3.3 VDC (3.1 to 3.5 VDC), 24 VDC (19.2 to 28.8 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 VAC continuous (1500 VAC for 1 minute input to backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRide-Through Duration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 ms minimum during source interruption\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eField Wiring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14 AWG to 22 AWG single wire per terminal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDaisy-Chain Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 4 PSA040 units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Air Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C (External Ambient)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eATEX Protection Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eII 3 G Ex nA IIC T3C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Diagnostics FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC695PSA040 power supply be configured in a parallel arrangement to achieve N+1 redundancy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This specific power supply is designed exclusively for solo operation within an RX3i Universal Backplane (IC695 catalog series). It cannot be paired with other power supplies to scale system capacity or provide hardware redundancy. Attempting to run older versions (version IC695PSA040C and earlier) alongside another supply inside the same backplane slot can cause severe equipment damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes the main Power LED indicator to turn from steady Green to Amber?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA Green light indicates that the module is powered up and successfully delivering stable DC rails to the backplane. An Amber light shows that input power is properly applied to the module's input wiring blocks, but the front-panel toggle switch is set to the OFF position, preventing power delivery to the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat underlying systemic failures cause a hard shutdown without throwing an external LED fault indicator?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA non-repairable internal fusible link resides in the input line as a final hardware backup. While the module usually activates electronic shutdown before this fuse fails, an extreme internal component short-circuit or an excessive input overvoltage surge can open this link permanently. When this fuse blows, all operational indications cease, and the module requires physical replacement.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Maintenance Protocol\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShock Hazard Mitigation \u0026amp; On\/Off Control Safety:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDuring active runtime with an AC power source, dangerous voltages (120 VAC or 240 VAC) exist on the internal circuit structures of the module. The front terminal access door must remain closed during standard runtime to prevent fatal shock hazards. Note that the front ON\/OFF toggle switch behind the door only controls the secondary DC output stages; it does NOT disconnect live incoming line power from the terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Insertion and Torque Limits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStrip all terminal conductors to a minimum length of 9 mm to 11 mm. Ensure the wire is fully inserted into the terminal housing until the conductor insulation sits flush against the internal insulation stop. Tighten the screw clamps carefully, ensuring you do not exceed the maximum allowable torque limit of 0.5 N-m (4.4 inch-lbs). Improper insertion can cause the screw clamp to bind on the wire insulation, leading to open circuits or hot termination points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOvervoltage Protection Jumper \u0026amp; Hi-Pot Testing Routine:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe bottom terminal blocks contain a Metal Oxide Varistor (MOV) surge circuit that must be connected to frame ground using a user-installed jumper for basic input overvoltage protection. To conduct a high-potential (Hi-pot) dielectric test on the supply, you must disable this overvoltage circuitry by removing this jumper. Reinstall the ground jumper immediately after testing is complete to restore transient protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695408443755,"sku":"IC695PSA040","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ic695psa040-power-supply-4shreuqch4g_da204954-e641-438e-bb05-ef59f1f08385.jpg?v=1766134971","url":"https:\/\/www.plcprotech.com\/fr\/products\/ge-fanuc-pacsystems-rx3i-ic695psa040-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}