{"product_id":"ge-fanuc-versamax-ic200alg320-analog-output-module","title":"Module de sortie analogique VersaMax GE Fanuc IC200ALG320","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-128\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eIC200ALG320 (IC200-ALG-320)\u003c\/strong\u003e\u003cspan class=\"citation-128 citation-end-128\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision, 4-channel analog output module from the GE VersaMax family.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is designed to provide unipolar voltage signals ranging from 0 to +10 VDC to control proportional valves, variable speed drives, and other actuators in industrial automation systems. Known for its compact footprint and ease of integration, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG320\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econverts digital data from the CPU or Network Interface Unit (NIU) into stable, low-noise analog signals. Its modular design allows for \"Hot-Swapping\" and easy DIN-rail mounting, making it a reliable choice for decentralized control in HVAC, water treatment, and light manufacturing applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module features a 12-bit resolution, ensuring granular control over the output signal. Each of the four channels is independent, although they share a common ground. The VersaMax architecture separates the module electronics from the field wiring via a terminal base (sold separately), which allows for permanent wiring and simplified maintenance.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-127 citation-end-127\"\u003eThe module includes internal diagnostics to monitor the health of the D\/A converters and provides LED status indicators for \"OK\" and \"User Power\" to facilitate rapid on-site troubleshooting.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ALG320\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax Analog I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage (Unipolar)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +10 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit (0 to 4095 counts)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.5% of full scale (at 25 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUpdate Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 4 ms for all 4 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 15%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.13 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.0 x 6.68 x 2.63 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power to operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC200ALG320 requires an external +24 VDC power supply to drive the analog output circuits. This power is usually supplied through the terminal base. If the \"User Power\" LED is off, the analog outputs will not function even if the PLC is in Run mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"Default\" behavior if the PLC stops communicating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDuring configuration in Proficy Machine Edition, you can set the \"Hold Last State\" or \"Output Default\" behavior. This ensures that if communication is lost, the 0-10V signal either stays at its current value or drops to a safe predefined voltage (usually 0V).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for 4-20mA current loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200ALG320 is a voltage-only module (0-10V). For current loop applications, you would need the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG321\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(which is the 0-20mA\/4-20mA equivalent).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Shielding:\u003c\/strong\u003e\u003cspan class=\"citation-126 citation-end-126\"\u003e\u003cspan\u003e \u003c\/span\u003eAnalog signals are highly susceptible to electromagnetic interference (EMI).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAlways use shielded twisted-pair (STP) cabling. The shield should be grounded at the PLC end (the terminal base) and left floating at the actuator end to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module is compatible with several terminal bases, such as the IC200TBT001 (Barrier style) or IC200TBP001 (Spring style). Ensure the base is correctly keyed to the \"Analog Output\" position to prevent the insertion of a different module type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the input impedance of the receiving device (e.g., a VFD) is at least 2 kOhms. Connecting a load with too low an impedance will cause the voltage to drop and may trigger a thermal overload within the module's output stage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695420305771,"sku":"IC200ALG320","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ge-fanuc-ic200alg320-versamax-analog-output-module-pr3ohiktwjj_b726736e-011b-4782-8e11-16d6e7be3b4a.jpg?v=1766135387","url":"https:\/\/www.plcprotech.com\/fr\/products\/ge-fanuc-versamax-ic200alg320-analog-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}