{"product_id":"ge-multilin-pqmii-t20-c-a-power-quality-meter","title":"Compteur de qualité d'énergie GE Multilin PQMII-T20-C-A","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin PQMII-T20-C-A\u003c\/strong\u003e is an industrial power quality monitoring device designed to perform continuous metering, electrical parameter analysis, and control functions within electrical substations and facility power networks. This fully optioned assembly integrates a baseline measurement module with a localized alphanumeric display panel to log all fundamental current, voltage, and power vectors. Equipped with the \u003cstrong\u003eT20\u003c\/strong\u003e transducer option, the module provides four isolated analog outputs and a 4-20 mA analog input alongside a secondary RS485 communication link. The \u003cstrong\u003eC\u003c\/strong\u003e control configuration expands system utility by adding three programmable output relays and four hardware switch inputs, while the \u003cstrong\u003eA\u003c\/strong\u003e power analysis suite implements harmonic evaluation, waveform capture, and dedicated voltage disturbance tracking directly inside the localized memory registers.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Power Metering\u003c\/strong\u003e: Tracks three-phase voltage and current waveforms alongside active, reactive, apparent power, and power factor vectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated Transducer Interface\u003c\/strong\u003e: Incorporates 4 isolated analog outputs (0-20 mA or 4-20 mA) assignable to any measured parameter and 1 specialized 4-20 mA analog input channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Relay Control\u003c\/strong\u003e: Features 4 programmable output relays and 4 discrete contact switch inputs to coordinate localized interlocking or alarm routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Quality Diagnostics\u003c\/strong\u003e: Provides advanced harmonic profiling, triggered trace memory capture, an internal event recorder, and data logging functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Data Networking\u003c\/strong\u003e: Outfitted with 2 independent serial RS485 communication interfaces and 1 dedicated front-access RS232 port.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUtility and commercial power substation tracking.\u003c\/li\u003e\n\u003cli\u003eMotor control center and distribution switchgear loading monitoring.\u003c\/li\u003e\n\u003cli\u003eHarmonic distortion profiling and power factor correction supervision.\u003c\/li\u003e\n\u003cli\u003eFeeder diagnostic capture and voltage disturbance logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model \/ Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePQMII\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic unit with display, all current\/voltage\/power measurements, one (1) RS485 port, one (1) RS232 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eT20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour (4) isolated analog outputs (0-20 mA \/ 4-20 mA), 4-20 mA analog input, second (2nd) RS485 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree (3) additional programmable output relays (total of 4), 4 programmable switch inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmonic analysis, triggered trace memory, waveform capture, event recorder, data logger, voltage disturbance recorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturing Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOntario, Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Quality Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Outputs (T20)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour (4) isolated channels, 0-20 mA or 4-20 mA assignable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs (T20)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne (1) channel, 4-20 mA configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Intf (C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 programmable switch inputs \/ 4 total programmable output relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalysis Package (A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmonic tracking, trace memory, event log, voltage disturbance recorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Interfacing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo (2) RS485 ports, One (1) RS232 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003ePanel Cutout and Mounting\u003c\/h3\u003e\n\u003cp\u003ePrepare a standard rectangular vertical panel opening matching the housing dimensions defined in the installation layout. Insert the meter from the front face of the dashboard frame and tighten the rear-accessed integrated clamp bolts evenly to seal the front bezel gasket against dust or moisture entry.\u003c\/p\u003e\n\u003ch3\u003eInstrument Transformer Connections\u003c\/h3\u003e\n\u003cp\u003eRoute all secondary voltage transformer (VT) and current transformer (CT) wires through localized external shorting or isolation switches. Ensure that no active current transformer secondary path becomes open-circuited while primary grid load is actively present.\u003c\/p\u003e\n\u003ch3\u003eTerminal Grounding\u003c\/h3\u003e\n\u003cp\u003eConnect a dedicated, low-impedance safety ground wire from the rear chassis grounding stud directly to the main copper station panel bus. Clean all contact surfaces of protective coatings or oxidation prior to fastening the grounding lug.\u003c\/p\u003e\n\u003ch3\u003eSerial Link Termination\u003c\/h3\u003e\n\u003cp\u003eWhen implementing long RS485 communication runs, install a matching 120-ohm termination resistor across the differential signal lines at the final terminal point of the network segment to suppress signal reflection and prevent telemetry corruption.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695411818859,"sku":"PQMII-T20-C-A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-pqmii-t20-c-a-power-quality-monitor-pxtapjssara_b7c29aef-e580-4a42-a0bb-87f0a0ca9b6a.jpg?v=1766135089","url":"https:\/\/www.plcprotech.com\/fr\/products\/ge-multilin-pqmii-t20-c-a-power-quality-meter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}