{"product_id":"general-electric-is200tgenh1a-mark-vi-speedtronic-termination-board","title":"Carte de terminaison General Electric IS200TGENH1A Mark VI Speedtronic  ","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200TGENH1A\u003c\/strong\u003e is a terminal board generator monitor designed by General Electric as part of the Mark VI Speedtronic turbine control system series. This termination board functions as the primary interface that collaborates with a core VGEN processor board to track three-phase generator voltages, bus voltages, and generator currents. Through these monitored signal sets, the processing architecture computes overall three-phase power, current frequencies, and the net system power factor. The \u003cstrong\u003eIS200TGENH1A\u003c\/strong\u003e features an integrated hardware arrangement comprising magnetically isolated current transformer (CT) inputs alongside potential transformer (PT) inputs, enabling full data collection across simplex and triple modular redundant (TMR) control layouts. To support diverse auxiliary control tasks, the device includes four adjustable analog inputs, a collection of local protective metal oxide varistors (MOVs), and discrete relays positioned centrally on the board surface. The entire printed circuit assembly is layered with a thin conformal coating to secure long-term component health when implemented within heavy utility power plants or steam turbine applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCommunicates directly with VGEN processors to compute three-phase power variables, frequency tracking, and power factors\u003c\/li\u003e\n\u003cli\u003eFormulated under a normal hardware assembly standard matching Mark VI system group one allocations\u003c\/li\u003e\n\u003cli\u003eOutfitted with a thin, complete layer of conformal PCB protective coating over the board footprint\u003c\/li\u003e\n\u003cli\u003eFeatures one long black terminal block alongside three smaller black terminal blocks for secure field connection loops\u003c\/li\u003e\n\u003cli\u003eIntegrates four large, square black relays containing specialized yellow centers directly in the middle of the PCB layout\u003c\/li\u003e\n\u003cli\u003eProtects analog paths with an integrated array of at least six circular red metal oxide varistors (MOVs)\u003c\/li\u003e\n\u003cli\u003eHosts three single-phase magnetically isolated current transformer (CT) inputs accepting high continuous ranges\u003c\/li\u003e\n\u003cli\u003eEmploys non-pluggable CT termination block points using captive lugs to maintain safety against open-circuit accidents\u003c\/li\u003e\n\u003cli\u003eIncludes three round white wire inductors covered with fabric, lined up vertically on the lower section\u003c\/li\u003e\n\u003cli\u003eFeatures onboard diagnostic limits with automated open-wire detection paths and monitored relay coil currents\u003c\/li\u003e\n\u003cli\u003eEquipped with three edge connector ports designated as JT1, JS1, and JR1, each hosting an independent electronic read-only ID chip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge steam turbine generator monitoring and power factor calculation\u003c\/li\u003e\n\u003cli\u003eThree-phase potential transformer and current transformer telemetry interfacing\u003c\/li\u003e\n\u003cli\u003eSimplex or triple modular redundant (TMR) turbine control panel integrations\u003c\/li\u003e\n\u003cli\u003eHigh-reliability analog transducer signal distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eIS200TGENH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VI Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTermination Board \/ Generator Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eTGEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevision Total\u003c\/td\u003e\n\u003ctd\u003e1 Revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Revision\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Type\u003c\/td\u003e\n\u003ctd\u003eNormal Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator and Bus Voltage Inputs\u003c\/td\u003e\n\u003ctd\u003eTwo 3-phase circuits (115 V RMS nominal; 50\/60 Hz nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Loading \/ Isolation\u003c\/td\u003e\n\u003ctd\u003eLess than 3 VA per circuit; Magnetic isolation up to 1,500 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Current Inputs\u003c\/td\u003e\n\u003ctd\u003eThree 1-phase circuits (0 to 5 A normal range; up to 10 A over-range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Loading \/ Isolation\u003c\/td\u003e\n\u003ctd\u003eLess than 0.5 input load per circuit; Magnetic isolation up to 1,500 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Frequency Range\u003c\/td\u003e\n\u003ctd\u003e45 to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4 channels (Adjustable for 4-20 mA or 5, 10, 20 V dc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Power Source\u003c\/td\u003e\n\u003ctd\u003e+24 V dc available for all four circuits (individual current limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Wire Terminal Accommodations\u003c\/td\u003e\n\u003ctd\u003eCaptive lugs accepting wires up to #10 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.00 x 9.00 x 3.00 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector \/ Terminal Designation\u003c\/th\u003e\n\u003cth\u003eFunction \/ Technical Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block 1 (TB1)\u003c\/td\u003e\n\u003ctd\u003eDedicated terminal block for analog current and potential transformer (PT) input lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB2, TB3, TB4\u003c\/td\u003e\n\u003ctd\u003eSpecial non-pluggable terminal blocks with captive lugs for current transformer (CT) wiring points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJT1 \/ JS1 \/ JR1\u003c\/td\u003e\n\u003ctd\u003eThree connector ports containing female pins located along the right border to link with VGEN processing cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator \/ Bus Test Points\u003c\/td\u003e\n\u003ctd\u003ePhysical probe test points provided on the board surface to manually verify input signal phases in the field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Configuration:\u003c\/strong\u003e Configure the J1A through J4A jumpers to specify whether the analog input channels 1 through 4 should receive current inputs or voltage inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReturn Path Configuration:\u003c\/strong\u003e Use jumpers J1B through J4B to define whether the return path of the corresponding analog channel is tied to common ground or left open based on your grounding scheme.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Transformer Wiring:\u003c\/strong\u003e Connect your CT sensor lines exclusively to the special terminal blocks TB2, TB3, and TB4, tightening the captive lugs securely around wires up to #10 AWG to eliminate any risk of open-circuit damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Interconnection:\u003c\/strong\u003e In simplex systems, connect a single interface cable from the board to the VGEN processor. For triple modular redundant (TMR) system layouts, run three distinct wires from connectors JR1, JS1, and JT1 to three separate VGEN processor boards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695420273003,"sku":"IS200TGENH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is200tgenh1a-termination-board-t21pzpqm32l_2f7c40ce-7827-471d-a54a-6287fce78933.jpg?v=1766135385","url":"https:\/\/www.plcprotech.com\/fr\/products\/general-electric-is200tgenh1a-mark-vi-speedtronic-termination-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}