{"product_id":"general-electric-is220paich1b-mark-vie-analog-i-o-pack","title":"Module d'Entrée\/Sortie Analogique General Electric IS220PAICH1B","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS220PAICH1B\u003c\/strong\u003e is a Mark VIe distributed \u003cstrong\u003eAnalog I\/O Pack\u003c\/strong\u003e designed for interfacing field analog signals with the control system. It supports voltage and current analog inputs, analog outputs, and integrated transmitter power functions within the GE Mark VIe platform. The module is approved for use with specific terminal boards including STAI and TBAI series accessories and is suitable for hazardous location installations when used according to GE installation requirements.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS220PAICH1B Analog I\/O Pack\u003c\/strong\u003e provides acquisition of analog process signals, output signal generation for field devices, and transmitter excitation power. It is commonly deployed in turbine control systems, process automation systems, balance-of-plant applications, and other industrial control environments utilizing the Mark VIe architecture. The module supports both voltage and current-based instrumentation and communicates through the Mark VIe distributed I\/O infrastructure.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports analog voltage inputs from -10 to +10 V dc\u003c\/li\u003e\n\u003cli\u003eSupports analog current inputs from 0 to 20 mA dc\u003c\/li\u003e\n\u003cli\u003eSupports additional analog input channels for specialized current and voltage measurements\u003c\/li\u003e\n\u003cli\u003eProvides analog output capability up to 20 mA\u003c\/li\u003e\n\u003cli\u003eIntegrated transmitter power output\u003c\/li\u003e\n\u003cli\u003eCompatible with Mark VIe control systems\u003c\/li\u003e\n\u003cli\u003eApproved for hazardous location installations\u003c\/li\u003e\n\u003cli\u003eCompatible with STAI and TBAI terminal board families\u003c\/li\u003e\n\u003cli\u003eIntrinsic Safety \"ic\" support when installed according to GE requirements\u003c\/li\u003e\n\u003cli\u003eUL, CSA, ATEX, and IEC hazardous location approvals available for certified configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGas turbine control systems\u003c\/li\u003e\n\u003cli\u003eSteam turbine control systems\u003c\/li\u003e\n\u003cli\u003ePower generation plants\u003c\/li\u003e\n\u003cli\u003eIndustrial process control systems\u003c\/li\u003e\n\u003cli\u003eCompressor control applications\u003c\/li\u003e\n\u003cli\u003eBalance-of-plant automation\u003c\/li\u003e\n\u003cli\u003eAnalog instrumentation monitoring\u003c\/li\u003e\n\u003cli\u003eProcess signal acquisition\u003c\/li\u003e\n\u003cli\u003eActuator and control signal output applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS220PAICH1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMark VIe Analog I\/O Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eMark VIe Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage (Min)\u003c\/td\u003e\n\u003ctd\u003e22.5 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage (Nominal)\u003c\/td\u003e\n\u003ctd\u003e24.0 \/ 28.0 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage (Max)\u003c\/td\u003e\n\u003ctd\u003e28.6 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e0.49 A dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs 1-8 Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-10 to +10 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs 1-8 Current Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs 9-10 Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-5 to +5 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs 9-10 Current Range\u003c\/td\u003e\n\u003ctd\u003e-1 to 20 mA dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 16.3 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Current Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Transmitter Power Voltage\u003c\/td\u003e\n\u003ctd\u003e22.8 to 25.2 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Transmitter Power Nominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24.0 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Transmitter Power Current\u003c\/td\u003e\n\u003ctd\u003e21 mA dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified in provided source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified in provided source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eSource data extracted directly from GEH-6725R PAIC\/YAIC Analog I\/O Module specifications.\u003c\/p\u003e\n\u003ch3\u003eApproved Terminal Boards\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory Terminal Board\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS200STAIH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS200STAIH2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS200TBAIH1C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS400STAIH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS400STAIH2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS400TBAIH1C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eApproved combinations are explicitly listed for IS220PAICH1B hazardous location installations.\u003c\/p\u003e\n\u003ch3\u003eIntrinsic Safety Analog Output Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoc \/ Uo\u003c\/td\u003e\n\u003ctd\u003e28.6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsc \/ Io\u003c\/td\u003e\n\u003ctd\u003e22.4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePo\u003c\/td\u003e\n\u003ctd\u003e0.64 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCa \/ Co\u003c\/td\u003e\n\u003ctd\u003e0.26 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLa \/ Lo\u003c\/td\u003e\n\u003ctd\u003e100 mH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eApplicable when used under Intrinsic Safety \"ic\" installation requirements.\u003c\/p\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB1.45\u003c\/td\u003e\n\u003ctd\u003eSignal 1 +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB1.46\u003c\/td\u003e\n\u003ctd\u003eReturn 1 -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB1.47\u003c\/td\u003e\n\u003ctd\u003eSignal 2 +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB1.48\u003c\/td\u003e\n\u003ctd\u003eReturn 2 -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB2.45\u003c\/td\u003e\n\u003ctd\u003eSignal 1 + (TBAI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB2.46\u003c\/td\u003e\n\u003ctd\u003eReturn 1 - (TBAI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB2.47\u003c\/td\u003e\n\u003ctd\u003eSignal 2 + (TBAI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB2.48\u003c\/td\u003e\n\u003ctd\u003eReturn 2 - (TBAI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eExtracted from the Intrinsic Safety field terminal assignments.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall only with approved STAI or TBAI terminal boards.\u003c\/li\u003e\n\u003cli\u003eMount within a suitable industrial control enclosure.\u003c\/li\u003e\n\u003cli\u003eFollow hazardous location installation requirements where applicable.\u003c\/li\u003e\n\u003cli\u003eUse copper conductors only.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding and shielding practices for analog signal wiring.\u003c\/li\u003e\n\u003cli\u003eSeparate low-level analog wiring from power conductors.\u003c\/li\u003e\n\u003cli\u003eObserve applicable intrinsic safety wiring requirements when used in hazardous locations.\u003c\/li\u003e\n\u003cli\u003eDo not connect or disconnect field wiring while circuits are energized in hazardous areas.\u003c\/li\u003e\n\u003cli\u003eFollow GE Mark VIe system installation documentation for power distribution and network integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification Type\u003c\/th\u003e\n\u003cth\u003eApproval\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL Certification\u003c\/td\u003e\n\u003ctd\u003eUL E207685\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Certification\u003c\/td\u003e\n\u003ctd\u003eUL DEMKO 13 ATEX 1214780X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass I Division 2\u003c\/td\u003e\n\u003ctd\u003eGroups A, B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass I Zone 2\u003c\/td\u003e\n\u003ctd\u003eGroup IIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Zone 2\u003c\/td\u003e\n\u003ctd\u003eGroup IIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Marking\u003c\/td\u003e\n\u003ctd\u003eClass I, Div 2, Groups A, B, C, D, T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZone 2 Marking\u003c\/td\u003e\n\u003ctd\u003eAEx nA nC [nC] IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Marking\u003c\/td\u003e\n\u003ctd\u003eEx ic nA [ic] IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eExtracted directly from Appendix A, Appendix B and Appendix C.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695408476523,"sku":"IS220PAICH1B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is220paich1b-analog-input-output-module-tdp4xvuaffm_3455c57f-1f49-4788-ae44-4f3c0a2ab21e.jpg?v=1766134971","url":"https:\/\/www.plcprotech.com\/fr\/products\/general-electric-is220paich1b-mark-vie-analog-i-o-pack","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}