{"product_id":"general-electric-is220pdiah1b-mark-vie-discrete-i-o-module","title":"Module d'E\/S Discret General Electric IS220PDIAH1B Mark VIe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS220PDIAH1B\u003c\/strong\u003e is a \u003cstrong\u003eDiscrete I\/O module\u003c\/strong\u003e designed for use within the \u003cstrong\u003eMark VIe\u003c\/strong\u003e control system platform. This industrial component operates as a high-reliability interface for discrete input processing in critical control and automation architectures. The \u003cstrong\u003eIS220PDIAH1B\u003c\/strong\u003e functions in coordination with certified terminal boards to process digital field signals under stringent hardware constraints. The device provides dedicated contact wetting outputs to interface securely with field switches and relay contacts. It is specifically certified for hardware applications deployed in hazardous locations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDedicated hardware processing for robust industrial discrete signaling.\u003c\/li\u003e\n\u003cli\u003eIntegrated contact wetting power framework supporting field devices.\u003c\/li\u003e\n\u003cli\u003eIntrinsic safety \"ic\" compatibility when paired with designated accessory terminal boards.\u003c\/li\u003e\n\u003cli\u003eSupport for multiple field connection block topologies including Euro-style and barrier blocks.\u003c\/li\u003e\n\u003cli\u003eBuilt-in transient voltage limiting mechanisms for reliable voltage regulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-availability industrial automation systems.\u003c\/li\u003e\n\u003cli\u003ePower generation and turbine control systems.\u003c\/li\u003e\n\u003cli\u003eCritical infrastructure and industrial process control applications.\u003c\/li\u003e\n\u003cli\u003eDistributed I\/O processing networks in hazardous areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscrete I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Framework\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark VIe Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Minimum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Nominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.0\/28.0 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Maximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.6 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Maximum Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.24 A dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Inputs Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 32 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Wetting Outputs (STCIH1A\/H2A\/TBCIH2C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 to 32 V dc, 110 mA dc max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Wetting Outputs 1-21 (STCIH8A\/TBCIH4C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31 V dc max, 10 mA dc max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Wetting Outputs 22-24 (STCIH8A\/TBCIH4C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31 V dc max, 41 mA dc max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot more than Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector\/Accessory Terminal Board\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Block Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200STCIH1A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuro Style Box-type Terminal Blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200STCIH2A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuro Style Box-type Terminal Blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200STCIH8A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuro Style Box-type Terminal Blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIS400STCIH1A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuro Style Box-type Terminal Blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIS400STCIH2A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuro Style Box-type Terminal Blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIS400STCIH8A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuro Style Box-type Terminal Blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200TBCIH2C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBarrier-type Terminal Blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIS400TBCIH2C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBarrier-type Terminal Blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIS200TBCIH4C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBarrier-type Terminal Blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Requirements:\u003c\/strong\u003e Install the open-type equipment inside a secure environmental enclosure that requires a tool or key to open.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Voltage Regulation:\u003c\/strong\u003e Ensure provisions are implemented to limit power supply transient voltages to less than 140% of the peak rated power supply voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Limitations:\u003c\/strong\u003e Power must be supplied through a certified power distribution board that limits the available current to 3.5 A maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring:\u003c\/strong\u003e Strip field wiring insulation locally without adding intermediate components other than standard bare conductor replication parts such as ferrules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Standards:\u003c\/strong\u003e Apply appropriate Class I Division 2 or Zone 2 wiring methods conforming to local codes and authority regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew Torques (Euro Blocks):\u003c\/strong\u003e Secure connections to a nominal torque of 4 in-lb (0.45 Nm) for wire sizes from 24 AWG to 12 AWG.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew Torques (Barrier Blocks):\u003c\/strong\u003e Secure connections to a nominal torque of 9.6 in-lb (1.1 Nm) for wire sizes from 22 AWG to 12 AWG.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695421878635,"sku":"IS220PDIAH1B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is220pdiah1b-i-o-pack-z450uqkfdje_4e7f3046-ac54-4b2b-860f-ada680568883.jpg?v=1766135448","url":"https:\/\/www.plcprotech.com\/fr\/products\/general-electric-is220pdiah1b-mark-vie-discrete-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}