{"product_id":"general-electric-is420yaics1b-mark-vie-analog-i-o-pack","title":"Pack d'E\/S analogique General Electric IS420YAICS1B Mark VIe","description":"\u003cp style=\"color:#2d3748;margin:0 0 12px 0;\"\u003e\nGE IS420YAICS1B is an Analog I\/O Pack designed for integration with Mark VIe and Mark VIeS control systems. The pack interfaces between a terminal analog I\/O board and up to two Ethernet networks while supporting \u003cstrong\u003eten analog input channels\u003c\/strong\u003e. It incorporates a \u003cstrong\u003ecommon processor board\u003c\/strong\u003e and a dedicated \u003cstrong\u003edata acquisition board\u003c\/strong\u003e, with diagnostic fault detection executed through the acquisition circuitry. The unit supports simplex and TMR architectures and is compatible with \u003cstrong\u003eTBAIS1C\u003c\/strong\u003e and \u003cstrong\u003eSTAIS2A\u003c\/strong\u003e terminal boards for turbine control applications in gas, steam, and wind power installations.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color:#1a365d;border-bottom:1px solid #d1d5db;padding-bottom:6px;\"\u003eFeatures\u003c\/h3\u003e\n\n\u003cul style=\"color:#2d3748;list-style-type:square;padding-left:20px;\"\u003e\n\u003cli\u003eAnalog I\/O Pack for Mark VIe and Mark VIeS control platforms\u003c\/li\u003e\n\u003cli\u003eInterfaces between terminal analog I\/O boards and Ethernet networks\u003c\/li\u003e\n\u003cli\u003eSupports up to ten analog input channels\u003c\/li\u003e\n\u003cli\u003eTwo channels configurable as plus or minus 1 mA or 4-20 mA current inputs\u003c\/li\u003e\n\u003cli\u003eEight channels configurable as plus or minus 5 V, plus or minus 10 V, or 4-20 mA current loop inputs\u003c\/li\u003e\n\u003cli\u003eDual RJ45 Ethernet communication ports\u003c\/li\u003e\n\u003cli\u003eDedicated processor board and data acquisition board architecture\u003c\/li\u003e\n\u003cli\u003e16-bit ADC input conversion resolution\u003c\/li\u003e\n\u003cli\u003ePower-up self-diagnostics for flash memory, RAM, processor hardware, and Ethernet ports\u003c\/li\u003e\n\u003cli\u003eContinuous monitoring of internal power supplies\u003c\/li\u003e\n\u003cli\u003eCompatible with simplex and TMR redundancy architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#1a365d;border-bottom:1px solid #d1d5db;padding-bottom:6px;\"\u003eApplications\u003c\/h3\u003e\n\n\u003cul style=\"color:#2d3748;list-style-type:square;padding-left:20px;\"\u003e\n\u003cli\u003eGas turbine control systems\u003c\/li\u003e\n\u003cli\u003eSteam turbine control systems\u003c\/li\u003e\n\u003cli\u003eWind turbine automation systems\u003c\/li\u003e\n\u003cli\u003ePower generation facilities\u003c\/li\u003e\n\u003cli\u003eAnalog process signal acquisition\u003c\/li\u003e\n\u003cli\u003ePlant instrumentation monitoring\u003c\/li\u003e\n\u003cli\u003eTurbine protection and control architectures\u003c\/li\u003e\n\u003cli\u003eRedundant control system deployments requiring TMR architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#1a365d;border-bottom:1px solid #d1d5db;padding-bottom:6px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003eMark VIe \/ Mark VIeS\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003eIS420YAICS1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eFunctional Abbreviation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003eYAIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eProcessor Board\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003eBPPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e5.3 Watts Typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eInput Converter Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e16-bit ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eSupported Analog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e10 Channels Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eEthernet Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003eDual RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eCompatible Terminal Boards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003eTBAIS1C, STAIS2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eRedundancy Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003eSimplex or TMR\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eControlST Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003eV06.01 and Later\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eCompatible Firmware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003eV05.01 or Later\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e-40 to 158 degF\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003eH 3.25 in x W 1.65 in x D 4.78 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eTechnical Manual\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003eGEH-6855 Volume I and II\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003eShipping Weight (Calculated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e1.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e\u003cstrong\u003ePackage Dimensions (Calculated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d1d5db;padding:8px;\"\u003e8 x 6 x 4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#1a365d;border-bottom:1px solid #d1d5db;padding-bottom:6px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\n\u003cdiv style=\"background:#fff5f5;border-left:5px solid #c53030;padding:12px;margin:12px 0;color:#742a2a;\"\u003e\n\u003cstrong\u003eCRITICAL WARNING\u003c\/strong\u003e\u003cbr\u003e\nDe-energize the Mark VIe rack, associated terminal board circuits, and all connected field instrumentation before installation or replacement. Verify lockout and tagout procedures are complete. Never insert or remove the I\/O pack while system power is present. Confirm that all TMR packs installed on the same terminal board are identical hardware versions before commissioning.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin:10px 0;\"\u003e\n\u003cspan style=\"display:inline-block;width:28px;height:28px;border-radius:50%;background:#2b6cb0;color:#ffffff;text-align:center;font-weight:bold;line-height:28px;\"\u003e1\u003c\/span\u003e\n\u003cspan style=\"color:#2d3748;\"\u003eInspect the pack housing, RJ45 ports, and backplane connector for mechanical damage before installation.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin:10px 0;\"\u003e\n\u003cspan style=\"display:inline-block;width:28px;height:28px;border-radius:50%;background:#2b6cb0;color:#ffffff;text-align:center;font-weight:bold;line-height:28px;\"\u003e2\u003c\/span\u003e\n\u003cspan style=\"color:#2d3748;\"\u003eVerify compatibility with the installed TBAIS1C or STAIS2A terminal board and confirm firmware requirements.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin:10px 0;\"\u003e\n\u003cspan style=\"display:inline-block;width:28px;height:28px;border-radius:50%;background:#2b6cb0;color:#ffffff;text-align:center;font-weight:bold;line-height:28px;\"\u003e3\u003c\/span\u003e\n\u003cspan style=\"color:#2d3748;\"\u003eSeat the pack fully into the terminal board assembly and verify positive connector engagement without side loading.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin:10px 0;\"\u003e\n\u003cspan style=\"display:inline-block;width:28px;height:28px;border-radius:50%;background:#2b6cb0;color:#ffffff;text-align:center;font-weight:bold;line-height:28px;\"\u003e4\u003c\/span\u003e\n\u003cspan style=\"color:#2d3748;\"\u003eConnect both Ethernet ports according to the control network architecture and verify network integrity.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin:10px 0;\"\u003e\n\u003cspan style=\"display:inline-block;width:28px;height:28px;border-radius:50%;background:#2b6cb0;color:#ffffff;text-align:center;font-weight:bold;line-height:28px;\"\u003e5\u003c\/span\u003e\n\u003cspan style=\"color:#2d3748;\"\u003eApply power and review diagnostic indicators, self-test results, and ControlST status before returning the unit to service.\u003c\/span\u003e\n\u003c\/div\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695412146539,"sku":"IS420YAICS1B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is420yaics1b-analog-i-o-pack-module-xj0t2shlsq5_384bc669-675d-4e30-8aa5-890946671d55.jpg?v=1766135101","url":"https:\/\/www.plcprotech.com\/fr\/products\/general-electric-is420yaics1b-mark-vie-analog-i-o-pack","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}