{"product_id":"hima-f3-dio-20-8-02-himatrix-safety-related-remote-i-o-module","title":"Module d'E\/S à distance lié à la sécurité HIMatrix HIMA F3 DIO 20\/8 02","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3 DIO 20\/8 02 (F3DIO20\/802)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact, high-integrity remote I\/O module designed for the HIMA HIMatrix safety system. Engineered to provide distributed safety-related control, this module integrates 20 digital inputs and 8 digital outputs within a ruggedized housing. It is a critical component for high-risk industrial environments such as oil and gas refineries, chemical processing plants, and offshore platforms where functional safety and maximum uptime are paramount. By leveraging the safeethernet protocol, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3 DIO 20\/8 02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables real-time, SIL 3 certified data transmission over standard Ethernet infrastructure. The specific 021 variant is built for extreme reliability, featuring protective lacquer coating to withstand harsh atmospheric conditions and extended temperature fluctuations, effectively eliminating unexpected system trips due to environmental stress.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3 DIO 20\/8 02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for functional safety and decentralized logic execution:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCertified for SIL 3 (IEC 61508) and Category 4 (EN 954-1) applications, ensuring the highest level of risk reduction for safety instrumented functions (SIF).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes dual Ethernet ports (10\/100BaseT) to support safeethernet communication, allowing for seamless integration into a safety network with deterministic response times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection (021 Variant):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComponents are coated with a specialized protective lacquer (conformal coating) to resist humidity and chemical corrosion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput\/Output Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures 20 safe digital inputs (supporting line control for short-circuit and wire-break detection) and 8 safe digital outputs (up to 2 A per channel, total max 15 A).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessing Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes an internal controller for localized signal processing, reducing the load on the central safety CPU and improving localized reaction times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF3 DIO 20\/8 02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHIMatrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 Channels (24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Channels (24 VDC, 2 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 3 \/ PLe \/ Cat. 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003esafeethernet (Ethernet IEEE 802.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC, -15 percent ... +20 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 x 145 x 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the specific advantages of the -20 Celsius model variant?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe -20 to +60 Celsius extended range, combined with the protective lacquer, allows the module to be installed in unheated outdoor cabinets or coastal environments where condensation and low temperatures would typically cause standard electronics to fail.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support line control for field sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The digital inputs are designed to perform line control by evaluating pulsed signals. This allows the system to differentiate between a valid signal, a wire break, or a short circuit in the field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the F3 DIO 20\/8 02 configured?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfiguration is handled via the SILworX engineering tool (or ELOP II Factory for legacy setups). The module parameters, such as error reaction and input delay, are set within the software and downloaded over the network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it possible to use this module in explosive atmospheres?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is ATEX Zone 2 certified, meaning it can be installed in areas where explosive atmospheres are unlikely to occur but may persist for a short time, provided it is housed in an appropriately rated enclosure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swapping and Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the HIMatrix system supports decentralized maintenance, replacing an F3 DIO module requires a safety verification. Always ensure the \"FORCE\" led is monitored during testing to prevent unintended actuation of final elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor cabinet installations, maintain a minimum vertical clearance of 100 mm to ensure adequate natural convection. Even though the module is rated for 60 Celsius, excessive heat density in a crowded cabinet can accelerate component aging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and EMC:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure SIL 3 communication integrity over safeethernet, use shielded RJ45 connectors and Category 5e (or higher) industrial-grade Ethernet cables. The DIN rail must be connected to a low-impedance functional earth to dissipate high-frequency interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 24 VDC supply should be sourced from a safety-approved power supply (SELV or PELV). Ensure that the voltage drop across long field cable runs does not fall below 20.4 VDC at the module terminals to avoid \"Undervoltage\" diagnostic faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":52695396450667,"sku":"F3DIO20\/802","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/hima-himatrix-f3dio20-802-remote-i-o-module-rkmnlgha4qy_acb48373-1b15-4d99-8e96-9be39d670b8e.jpg?v=1766133411","url":"https:\/\/www.plcprotech.com\/fr\/products\/hima-f3-dio-20-8-02-himatrix-safety-related-remote-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}