{"product_id":"hima-hiquad-f-6214-4-fold-analog-input-module-safety-related","title":"Module d'entrée analogique 4 voies lié à la sécurité HIMA HIQuad F 6214","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eF 6214 (F6214)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a safety related 4 channel analog input module designed for HIMA HIQuad systems. It processes 4 to 20 mA transmitter signals, voltage inputs from 0 to 10 V, and current inputs up to 20 mA with galvanic isolation. The module supports safety critical signal acquisition in industrial automation environments such as oil and gas, power generation, and chemical processing.\u003c\/p\u003e\n\u003cp\u003eThe module integrates 12 bit resolution signal conversion and ensures stable measurement performance under demanding operating conditions. It provides transmitter power supply and built in input filtering to reduce electrical noise. Engineers use it to improve process safety integrity and reduce unplanned shutdowns in critical control loops.\u003c\/p\u003e\n\u003cp\u003eThe design supports requirement class AK 1 to 6, ensuring compliance with safety related applications. The isolation architecture protects downstream systems from field wiring faults. It is widely deployed in redundant safety instrumented systems where reliability and fast diagnostics are required.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eF 6214 does not use a multi level suffix structure. Configuration is defined by channel type and safety application class.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eF 6214: Safety related analog input module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e4 fold: Four independent input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog input support: Voltage and current signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety isolation: Galvanic separation between field and system side\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAK 1 to 6: Requirement class for safety integrity applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe module architecture is built around isolated input channels with independent signal conditioning. Each channel processes analog signals through filtering and analog to digital conversion with 12 bit resolution.\u003c\/p\u003e\n\u003cp\u003eIt supports mixed signal acquisition including 4 to 20 mA loops and voltage measurement inputs. The system integrates diagnostic monitoring for input wiring faults, overload conditions, and signal deviation detection.\u003c\/p\u003e\n\u003cp\u003eIsolation barriers ensure separation between field devices and control system electronics. This reduces risk during fault conditions and improves system availability in safety critical environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eItem\u003c\/th\u003e\n\u003cth class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF 6214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4 TE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 V DC 150 mA, 24 V DC 250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat signal types does the F 6214 support?\u003c\/strong\u003e\u003cbr\u003eIt supports 4 to 20 mA, 0 to 20 mA, and voltage inputs from 0 to 10 V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module provide channel isolation?\u003c\/strong\u003e\u003cbr\u003eYes, it provides safety isolation between field inputs and system electronics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan unused channels remain open?\u003c\/strong\u003e\u003cbr\u003eNo, unused channels must be terminated according to planning rules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the resolution of signal conversion?\u003c\/strong\u003e\u003cbr\u003eThe module provides 12 bit resolution for analog signal processing.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eInstall the module inside a certified control cabinet with proper grounding to the system earth bar. Use shielded twisted pair cables for all analog inputs to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eMaintain adequate airflow inside the cabinet to prevent heat accumulation. Keep spacing between modules according to rack design to ensure stable thermal conditions.\u003c\/p\u003e\n\u003cp\u003eAvoid routing analog signal cables near high voltage or high current conductors. This reduces noise coupling and improves measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eApply proper shielding termination at one end only to avoid ground loops. Verify isolation integrity before commissioning.\u003c\/p\u003e\n\u003cp\u003eIn hazardous environments, ensure enclosure compliance with zone classification requirements and follow all installation safety documentation.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":52695400382827,"sku":"F6214","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/hima-f6214-analog-input-module-qdqbmcixb2r_5eecc312-f81f-43e7-9640-b7bf19bf8365.jpg?v=1766133704","url":"https:\/\/www.plcprotech.com\/fr\/products\/hima-hiquad-f-6214-4-fold-analog-input-module-safety-related","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}